Solid Vent Kit Install Instructions
8
6. Insert the straight end of the three (3) inch (7.6 cm) diameter elbow into
the flue reducer until firmly seated and oriented in the correct direction.
With a 1/8 inch (3.0 mm) diameter drill bit (not supplied), drill three (3)
holes, 120
o
apart, through the flue reducer into the three (3) inch (7.6
cm) diameter elbow. Fasten with three (3) #8 sheet metal screws
(supplied). Using the supplied special RTV silicone sealant, apply a
sufficient amount to seal the joint (See Figure 5).
Figure 5
7. Place the straight end of the five (5) inch (12.7 cm) diameter elbow over
the three (3) inch (7.6 cm) diameter elbow and plenum collar until
seated on top of the plenum box. Make certain that the five (5) inch
(12.7 cm) diameter elbow is oriented in the same direction as the three
(3) inch (7.6 cm) diameter elbow and both are oriented in the correct
direction. Drill three (3) 1/8 inch (3.0 mm) diameter holes, 120
o
apart,
through the five (5) inch (12.7 cm) diameter elbow into the plenum
collar. Fasten with three (3) #8 sheet metal screws (supplied) (See
Figure 6).