Solid Vent Kit Install Instructions
12
Figure 10
12. From inside the building, slide the backing plate over the five (5) inch
(12.7 cm) diameter telescopic tube until it is flush with the wall. Adjust
the length of the five (5) inch (12.7 cm) diameter telescopic tube and
insert the end into the flared end of the five (5) inch (12.7 cm) diameter
elbow one (1) inch (2.5 cm) (or until seated). Drill three (3) 1/8 inch (3.0
mm) diameter holes, 120
o
apart, through the five (5) inch (12.7 cm)
diameter elbow into the five (5) inch (12.7 cm) diameter telescopic tube
and through the tubes where the small and large sections overlap.
Fasten with three (3) #8 sheet metal screws (supplied). Using the
supplied special RTV silicone sealant, apply a sufficient amount to seal
all joints (See Figure 11).
Figure 11