Spec Sheet
Residential Direct Vent Water Heater
NATURAL GAS AND LIQUID PROPANE GAS
High Input Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor
to Center
Line of
Vent
in.
B
Jacket
Dia.
in.
Capacity Recovery at
90°F Rise*
DH1-504T6FBN
DH1-65T6FBN
DH1-75S6FBN
U.S.
Gal.
48
65
75
Imp.
Gal.
40
54
62
Nat.
BTU/Hr.
Input
50,000
55,000
60,000
LP
BTU/Hr.
Input
48,000
55,000
57,000
Nat.
U.S.
GPH
53
58
63
Nat.
Imp.
GPH
43
47
51
LP
U.S.
GPH
50
58
60
LP
Imp.
GPH
41
47
48
75
1
/
4
min.
78
1
/
4
min.
75
1
/
2
min.
190
226
261
20
22
24
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor
to Center
Line of
Vent
mm.
B
Jacket
Dia.
mm.
Capacity Recovery at
50°C Rise*
DH1-504T6FBN
DH1-65T6FBN
DH1-75S6FBN
Liters
182
246
284
Nat.
kW
Input
14.7
16.1
17.6
LP
kW
Input
14.1
16.1
16.7
LP
Liters/
Hour
189
220
227
Nat.
Liters/
Hour
201
220
238
1411 min.
1988 min.
1918 min.
K
Depth
in.
31
1
/
4
34
1
/
4
35
1
/
4
K
Depth
mm.
768
864
889
F
Floor
to Top
of Heater
in.
58
3
/
4
62
59
F
Floor
to Top
of Heater
mm.
1492
1575
1499
G
Floor to
Space
Heating
Outlet
in.
52
1
/
4
56
52
G
Floor to
Space
Heating
Outlet
mm.
1327
1422
1320
J
Floor to
Space
Heating
Inlet
in.
15
3
/
4
15
3
/
4
16
1
/
2
J
Floor to
Space
Heating
Inlet
mm.
400
400
419
E
Floor
to Gas
Conn.
in.
15
15
15
E
Floor
to Gas
Conn.
mm.
381
381
381
D
Floor
to T&P
Conn.
in.
52
1
/
4
56
52
D
Floor
to T&P
Conn.
mm.
1327
1422
1321
H
Floor
to Water
Conn.
in.
59
3
/
4
63
60
H
Floor
to Water
Conn.
mm.
1518
1600
1524
C
Vent
Size
in.
4-6
4-6
4-6
C
Vent
Size
mm.
102-152
102-152
102-152
86
102
118
508
559
610
C
A
B
F
E
H
7
3
/
4
"
K
D&G
J
C
A
E
7
3
/
4
"
K
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT
(19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX".
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
Telescoping Solid Vent Kit (239-47811-00) or Flexible Vent Kit (239-47813-00) can be ordered and shipped with water heater,
or ordered and shipped separately.
For vent kit components and venting instructions, refer to Installation and Operating Manual.
Optional Telescoping Solid Vent Kits:
Kit “F” Telescopes from 4
3
⁄4" to 5
11
⁄16" Part No. 239-42516-00
Kit “G” Telescopes from 6
1
⁄2" to 9
3
⁄16" Part No. 239-42517-00
Kit “H” Telescopes from 13
3
⁄4" to 23
11
⁄16" Part No. 239-42514-00
Kit “I” Telescopes from 49
13
⁄16" to 95
13
⁄16" Part No. 239-42512-00
Printed in U.S.A.
105-B-0314-A
©2014, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
●
Fax 215-641-1670 / Technical Support 800-334-3393
●
Fax 269-795-1089
●
Warranty 800-531-2111
●
Fax 269-795-1089
International: Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www.bradfordwhite.com
Flexible Vent Kit (Side View) Telescoping Solid Vent Kit (Side View)