Product Overview

Residential Direct Vent Water Heater
N
ATURAL GAS AND LIQUID PROPANE GAS
High Input Energy Saver Models
M
eet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
M
odel
Number
Approx.
S
hipping
Weight
lbs.
A
F
loor
to Center
Line of
V
ent
in.
B
J
acket
Dia.
in.
Capacity Recovery at
9
0°F Rise*
D
H1-504T6FBN
DH1-65T6FBN
DH1-75S6FBN
U.S.
G
al.
4
8
65
75
Imp.
G
al.
4
0
54
62
N
at.
BTU/Hr.
I
nput
5
0,000
55,000
60,000
L
P
BTU/Hr.
I
nput
4
8,000
55,000
57,000
N
at.
U.S.
G
PH
5
3
58
63
N
at.
Imp.
G
PH
4
3
47
51
L
P
U.S.
G
PH
5
0
58
60
L
P
Imp.
G
PH
4
1
47
48
7
5
1
/
4
78
1
/
4
75
1
/
2
1
90
226
261
2
0
22
24
Model
N
umber
Approx.
Shipping
W
eight
k
g.
A
Floor
t
o Center
Line of
V
ent
m
m.
B
Jacket
D
ia.
m
m.
Capacity Recovery at
50°C Rise*
DH1-504T6FBN
DH1-65T6FBN
DH1-75S6FBN
Liters
182
246
284
Nat.
k
W
Input
14.7
16.1
17.6
LP
k
W
Input
14.1
16.1
16.7
LP
L
iters/
Hour
189
220
227
Nat.
L
iters/
Hour
201
220
238
1411
1988
1918
K
D
epth
in.
3
1
1
/
4
34
1
/
4
35
1
/
4
K
Depth
m
m.
768
864
889
F
F
loor
to Top
of Heater
in.
5
8
3
/
4
62
59
F
Floor
t
o Top
of Heater
m
m.
1492
1575
1499
G
F
loor to
Space
Heating
O
utlet
in.
5
2
1
/
4
56
52
G
Floor to
S
pace
Heating
O
utlet
m
m.
1327
1422
1320
J
F
loor to
Space
Heating
I
nlet
in.
1
5
3
/
4
15
3
/
4
16
1
/
2
J
Floor to
S
pace
Heating
I
nlet
m
m.
400
400
419
E
F
loor
to Gas
Conn.
in.
1
5
15
15
E
Floor
t
o Gas
Conn.
m
m.
381
381
381
D
F
loor
to T&P
Conn.
in.
5
2
1
/
4
56
52
D
Floor
t
o T&P
Conn.
m
m.
1327
1422
1321
H
F
loor
to Water
Conn.
in.
5
9
3
/
4
63
60
H
Floor
t
o Water
Conn.
m
m.
1518
1600
1524
C
V
ent
Size
in.
4
-6
4-6
4-6
C
Vent
S
ize
m
m.
102-152
102-152
102-152
86
102
118
508
559
610
C
A
B
F
E
H
7
3
/
4
"
K
D&G
J
C
A
E
7
3
/
4
"
K
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT
(19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX".
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
T
elescoping Solid Vent Kit (239-47811-00) or Flexible Vent Kit (239-47813-00) can be ordered and shipped with water heater,
or ordered and shipped separately.
For vent kit components and venting instructions, refer to Installation and Operating Manual.
Optional Telescoping Solid Vent Kits:
Kit “F” Telescopes from 4
3
4" to 5
1
1
16" Part No. 239-42516-00
Kit “G” Telescopes from 6
1
2" to 9
3
1
6
" Part No. 239-42517-00
Kit “H” Telescopes from 13
3
4" to 23
11
16" Part No. 239-42514-00
Kit “I” Telescopes from 49
1
3
16" to 95
1
3
16" Part No. 239-42512-00
Printed in U.S.A.
105-B-0211-A
©2011, Bradford White Corporation. All rights reserved.
Ambler
, PA
For U.S. and Canada field ser
vice, contact your pr
ofessional installer or local Bradfor
d White sales r
epresentative.
Sales 800-523-2931
Fax 215-641-1670 / T
echnical Suppor
t
800-334-3393
Fax 269-795-1089
W
ar
ranty
800-531-2111
Fax 269-795-1089
International:
Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / T
echnical Suppor
t
866-690-0961 / 905-238-0100
Fax 905-238-0105 / www
.bradfor
dwhite.com
Flexible V
ent Kit (Side View)
T
elescoping Solid Vent Kit (Side View)