Install Instructions

23
MAINTENANCE
In addition, the following steps should be performed at six-month intervals unless
otherwise specified:
1. Make sure you clear the combustion air openings of any dust, lint or other
restrictions. Flow of combustion air MUST NOT be restricted.
2. Check the burner flame periodically. If it becomes out of shape or smoky,
call your service technician.
3. When cleaning your heater room or utility room, always turn off the burner
to reduce the amount of dust and lint drawn into the burner.
4. The electric ignition system and all controls should be checked
periodically for reliability of operation and adjusted if necessary.
5. Lightly oil the burner motor with "Medium" detergent-free automobile
engine oil twice per year.
6. Clean Strainer or Filter as follows:
a) Oil valves between oil storage tank and burner should be shut.
b) Remove Strainer cover.
c) Remove Strainer baskets and wash in kerosene.
d) Reassemble.
7. Drain off at least one gallon of water each month to remove the silt and
sediment from the water heater.
CAUTION: THIS WATER MAY BE HOT.
8.
Check the temperature-pressure relief valve to insure that the valve has
not become inoperable. Lift the lever at the top of the valve several times
until the valve seats properly without leaking and operates freely.
CAUTION: THIS WATER MAY BE HOT.
If the temperature and pressure relief valve on the water heater discharges
periodically, this may be due to thermal expansion in a closed water supply
system. Please contact your water supplier or plumbing professional on how to
correct this situation. Do not plug the temperature and pressure relief valve.
Either a plug type, combination anode/nipple or both have been installed in this
water heater to extend tank life. The anode(s) should be inspected periodically
(every 2 years) and replaced if necessary. Contact the installing professional
plumber or the manufacturer listed on the rating plate for replacement anode
information. The use of a water softener may increase the speed of anode
consumption. More frequent inspection of the anode is needed when using
softened (or phosphate treated) water. You should contact your supplier or a
plumbing professional for replacement parts. Make sure that you give the Part
name, model number and serial number of the water heater when ordering the
parts.
WARNING
When lifting the lever of the temperature and pressure relief valve, hot
water will be released under pressure. Be certain that any released
water does not result in bodily injury or property damage.