4. The vent shall terminate a minimum of 12” (25.4 cm) above expected snowfall level
to prevent blockage of vent termination.
Vent pipes serving power vented appliances are classified by building codes as
“vent connectors”. Required clearances from combustible materials must be
provided in accordance with information in this manual under Locating the
Water Heater” and “Minimum Clearances, and with National Fuel Gas Code
and local codes.
Clearance to combustibles for all venting pipes and
terminals
For installations in the US
0” minimum
For installations in the CANADA
Refer to vent pipe and terminal
manufacturer’s installation
instructions for clearances to
combustibles
DO NOT place insulation or other materials in the required clearance spaces
between the venting to combustible material unless otherwise specified.