Spec Sheet

NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
Capacity
Combi1
®
Models
F
Floor
to
Exchanger
Inlet
in.
C
Vent
Size
in.
Approx.
Shipping
Weight
lbs.
E
Floor
to
Gas
Conn.
in.
A
Floor to
Flue
Conn.
in.
D
Floor to
T&P
Conn.
in.
J
Floor
to
Water
Conn.
in.
B
Jacket
Dia.
in.
Gal.
U.S.
Input
Nat.
BTU/Hr.
Input
LP
BTU/Hr.
GPH
Nat.
U.S.
Recovery
90°F Rise*
Model
Number
Capacity
Liters
F
Floor
to
Exchanger
Inlet
mm.
C
Vent
Size
mm.
Approx.
Shipping
Weight
kg.
E
Floor
to
Gas
Conn.
mm.
A
Floor to
Flue
Conn.
mm.
D
Floor to
T&P
Conn.
mm.
J
Floor
to
Water
Conn.
mm.
B
Jacket
Dia.
mm.
Input
Nat.
kW
Input
LP
kW
Hour
Nat.
Liters/
Hour
LP
Liters/
Recovery
50°C Rise*
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
72
Gal.
Imp.
61 76,000 76,000 62 26 63
1
4
292
45
929
5
813
7
851
3
4 51
3
481
GPH
LP
U.S.
81
GPH
Nat.
Imp.
70
GPH
LP
Imp.
70
C-SW2-75T10BN
C-SW2-75T10BN
272 317 1581 660 1314 352 752
G
Floor
to
Exchanger
Outlet
in.
G
Floor
to
Exchanger
Outlet
mm.
1314
H
Floor
to
Top of
Heater
in.
H
Floor
to
Top of
Heater
mm.
30
3
8
1499102 1281600
K
Depth
in.
K
Depth
mm.
77222.322.3 317
Residential Atmospheric Vent Gas Water Heater System
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3/4" NPT
(19mm) on 11" (203mm) centers. All heat exchanger connections are 1" NPT (25mm). All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER
be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the
unit may be used in space heating applications.
Propane model features a Titanium Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”.
*Based on manufacturers rated recovery efficiency.
*These values were obtained using 180°F stored tank temperature.
Net Output is the space heating capacity based on normal piping and pickup
allowance of 15%.
Actual values may vary based on circulator flow rate, number of zones, water
and space heating demands. Numbers subject to change.
K
C
B
A
J
H
E
F
D & G
PLUG TYPE
ANODE
K
C
B
A
J
H
E
F
D & G
PLUG TYPE
ANODE
©2022, Bradford White Corporation, USA. All rights reserved.
Printed in U.S.A.
Customer Service / Sales: 1-866-690-0961 / 905-203-0600
24/7 Technical Support: 800-334-3393
n
Email techserv
@
bradfordwhite.com
C548-G-0422 CANADA
Heat Exchanger
Head Loss
GPM
2
5
8
10
12
Ft. of
Hd. Loss
0.03
0.20
0.51
0.80
1.15
Heat Exchanger
Head Loss
LPM
7.6
18.9
30.2
37.9
45.4
m of
Hd. Loss
0.0091
0.0609
0.1554
0.2438
0.3505
Heat Exchanger Values*
Supply Temperature
Return Temperature
Differential
Flow Rate
Net Output
140°F
120°F
20°F
4.1 GPM
35,500 BTU/Hr.
60°C
49°C
11°C
15.5 LPM
10.4 kW
49°C
38°C
11°C
21.2 LPM
14.0 kW
38°C
27°C
11°C
21.2 LPM
14.0 kW
120°F
100°F
20°F
5.6 GPM
47,500 BTU/Hr.
100°F
80°F
20°F
5.6 GPM
47,500 BTU/Hr.