Installation / Operation Instruction Manual
7
Minimum Clearances continued-
This installation must allow access to the front of the water heater and
adequate clearance must be provided for servicing and operating this water
heater. The water heater may be installed on either a combustible or non-
combustible floor. If the water heater is to be installed directly on carpeting, it
must be installed on top of a metal or wood panel (or equivalent) extending
beyond the full width and depth of the appliance by at least 3 in (7.6 cm) in any
direction or, if the appliance is to be installed in an alcove or closet, the entire
floor must be covered by the panel, increase distances to provide clearance
for servicing. If the rating plate or the label on the front of the water heater
specifies minimum clearances less than those listed in the below table,
the water heater may be installed in accordance with the minimum
clearances listed on the rating plate or the label on the front of the water
heater.
If it is necessary to install this water heater in an alcove, use the clearances
listed in the following table and Figure 1.
Minimum Clearances From
Combustible Materials
For Alcove Installation
A 6” (15.2 cm)
B 6” (15.2 cm)
C 16” (40.6 cm)
VENT 6” (15.2cm)
Figure 1
Venting
WARNING
The venting system must be installed properly following all local codes
or in the absence of local codes, the latest edition of the National Fuel
Gas Code (ANSI Z223.1- latest edition), or in Canada, The Natural Gas
and Propane Installation Code (B149.1-00 latest edition). Failure to
properly install the venting system could result in property damage,
personal injury, or death.