Options & Accessories
800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors)
20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 (Applications Engineering)
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130
www.Laars.com
Document 1427-BW
Common Venting for Brute
pg 3 of 7
D
C
C
D
8
7
6
5
4
3
2
1
BY LAARS HEATING SYSTEMS CO.
DWG
DWG
DWG
REVISIONS
REV.
CHANGE:
APPR
ENGR APPR
ECN
DRAFT
DISCLOSED TO OTHERS FOR MANUFACTURING OR ANY OTHER
PURPOSE EXCEPT AS SPECIFICALLY AUTHORIZED IN WRITING
REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, USED OR
CHECK
DWG
THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN ARE
PROPRIETARY TO LAARS HEATING SYSTEMS CO. AND SHALL NOT BE
5
2
6
2
7
4
6
8
Exhaust
SHEET 1 OF 1
D
DWG. NO:
ENGR
INTENDED SIZE:
APPROVALS
REV.
B
A
B
1
2
3
4
5
6
7
.1
SCALE: NONE
DRAFT
SOFTWARE
APPR
D
W
G
N
O
.
8
DWG
S
H
S
.010
1
PROJECT NO.
DECIMALS .XX
R
E
V
1/8"
FINISH
MATERIAL:
TOLERANCES ARE:
1
DECIMALS .XXX
TITLE:
FRACTIONS
.03
DECIMALS .X
DIMENSIONS ARE IN INCHES.
UNLESS OTHERWISE SPECIFIED:
ANGLES
DO NOT SCALE DRAWING.
THIRD ANGLE PROJECTION.
PROJ
2
1
3
2
Included in
Non-Return
Valve Kit
5
2
2
4
2
1
3
2
Included in
Non-Return
Valve Kit
D
C
C
D
8
7
6
5
4
3
2
1
BY LAARS HEATING SYSTEMS CO.
DWG
REVISIONS
REV.
CHANGE:
APPR
ENGR APPR
ECN
DRAFT
CHECK
DWG
PURPOSE EXCEPT AS SPECIFICALLY AUTHORIZED IN WRITING
DWG
DWG
DISCLOSED TO OTHERS FOR MANUFACTURING OR ANY OTHER
REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, USED OR
THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN ARE
PROPRIETARY TO LAARS HEATING SYSTEMS CO. AND SHALL NOT BE
5
5
6
2
9
2
2
2
6
Air Intake
SOFTWARE
INTENDED SIZE:
SCALE: NONE
R
E
V
B
A
B
1
2
3
4
5
6
7
DWG. NO:
D
SHEET 2 OF 2
S
APPROVALS
8
D
W
G
N
O
.
S
H
REV.
DWG
1
PROJECT NO.
.010
DECIMALS .XX
1/8"
FINISH
MATERIAL:
TITLE:
TOLERANCES ARE:
FRACTIONS
DECIMALS .XXX
.1
1
.03
DECIMALS .X
DIMENSIONS ARE IN INCHES.
UNLESS OTHERWISE SPECIFIED:
APPR
ENGR
DRAFT
ANGLES
DO NOT SCALE DRAWING.
THIRD ANGLE PROJECTION.
PROJ
4
1
2
4
2
1
2.B Required Components
At minimum, the following components are required to install a common vent system.
Exhaust
Air Intake
(if using
Centrotherm
InnoFlue)
Item
#
Mfg.
Part #
Venting
Component
1
ISAGLxxxx
1
Appliance Adapter for Coupler
Style Flue Collar
2
IANSxx
Connector Ring
3
N/A
2
Non-Return Valve (NRV)
4
ISVLxxx
Vent Length
5
ISELxxxx
87
o
Elbow
6
ISBTxxxxxx
Branch Tee
7
ISHDTxx
Horizontal Drain Tee
8
IASJBVS
Universal Ball Valve Siphon
9
ISTCxx
Tee Cap
Table 3: Venting Components
1. “xx”, “xxx”, etc., refers to variations in nominal size.
See Centrotherm’s catalog for a particular application.
2. Non-Return Valve must be purchased from Laars.
Changes to Bradford White Manual Only
Kit Number
Description
CA016403
Non-Return Valve Kit, Brute 80 - 105
CA016404
Non-Return Valve Kit, Brute 150 - 210
CA016405
Non-Return Valve Kit, Brute 285 - 500
Table 1: Non-Return Valve Kit Part Numbers
2. Non-Return Valve must be purchased
from Bradford White