Installation / Operation Instruction Manual

Page 5
Brute
HIGH EFFICIENCY COMMERCIAL BOILERS AND VOLUME WATER HEATERS
®
SECTION 1
GENERAL INFORMATION
1.A Introduction
2 3 4 5 6 7 8 9 10 11
SERIES
Bradford White
Brute
USAGE
H - HYDRONIC
V - VOLUME
WATER
SIZE
MBTU/h
1 5 0
1 9 9
2 1 0
2 8 5
3 9 9
5 0 0
6 0 0
7 5 0
8 5 0
FUEL
N - NATURAL
P - PROPANE
OPTIONS CODE
X - STANDARD
J - CSD-1, FM, GAP,
IL (500-850 only)
C - STANDARD (Canada)
D - CSD-1 (Canada)
E - OUTDOOR
F - OUTDOOR (Canada)
G - CSD-1, OUTDOOR
H - CSD-1, OUTDOOR
(Canada)
PUMP OPTIONS
N - PUMP INCL.
(Available all
models except
outdoor 750BNTV
& 850 BNTV)
X - NO PUMP
W - HLW w/PUMP
(opt for BNTV only)
L - HLW w/out
PUMP
(opt for BNTV only)
REVISION
3 - THIRD
3
N T
1
B
Consult the Rating Plate on the side of the unit. The
following information describes the Model Identication
(Model Nomenclature).
(1-3) Model Series Designation
B N T = Bradford White, Brute
(4) Usage
H = Hydronic
V = Volume Water
(5-7) Size
1 5 0 = 150,000 BTU/hr input
1 9 9 = 199,000 BTU/hr input, BNTV only
2 1 0 = 210,000 BTU/hr input, BNTH only
2 8 5 = 285,000 BTU/hr input
3 9 9 = 399,000 BTU/hr input
5 0 0 = 500,000 BTU/hr input
6 0 0 = 600,000 BTU/hr input
7 5 0 = 750,000 BTU/hr input
8 5 0 = 850,000 BTU/hr input
(8) Fuel
N = Natural Gas
P = LP Gas
(9) Options Code
X = Standard Unit
J = CSD-1, FM, GAP, IL Code (size 500-850 only)
C - STANDARD (Canada)
D - CSD-1 (Canada)
E - OUTDOOR
F - OUTDOOR (Canada)
G - CSD-1, OUTDOOR
H - CSD-1, OUTDOOR (Canada)
(10) Pump Options
N = Pump included (available all models except
outdoor 750 BNTV & 850 BNTV)
X = No pump (conguration available for all sizes)
W = HLW w/ Pump (option for BNTV only)
L = HLW w/out Pump (option for BNTV only)
(11) Revision
3 = Third version
Bradford White products are covered by a limited
warranty. The owner should complete the warranty
registration at www.BradfordWhite.com.
All warranty claims must be made to an authorized
Bradford White Representative. Claims must include
the serial number and model (this information can be
found on the rating plate), installation date, and name
of the installer. Shipping costs are not included in the
warranty coverage.
This manual provides information necessary for the
installation, operation, and maintenance of Bradford
White’s Brute boilers and water heaters. Read it
carefully before starting the installation.
All application and installation procedures should
be reviewed completely before proceeding with the
installation. Consult a Bradford White representative,
with any problems or questions regarding this
equipment. Experience has shown that most operating
problems are caused by improper installation.
Brute units are protected against over pressurization. A
pressure relief valve is included with each Brute. Some
Brute models may require that the PRV be installed
prior to lling the system. Refer to Figures 2-9 for PRV
locations.
NOTE: Throughout the content of this manual,
the Brute will be referred to as a ‘unit’.
Brute = unit
1.B Warranty
1.C Model Identication