Specication
Brute Plate
Commercial Indirect Water Heater
Model BLP
Specification
Contractor shall supply and install Qty.: _____ Bradford White Model No. BLP- ______D high efficiency plate and frame water
heater(s).
The heater shall be a Bradford White, Bute Plate Model ___________, rated at the temperatures and water flows shown on the
schedule.
The heater shall be constructed and stamped in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII, Division
I, for a boiler-side working pressure of 150 psi and 220°F temperature, and a domestic side working pressure of 150 psi. The heater
shall be rated in accordance with ANSI/AHRI Standard 400 (I-P), Performance Rating of Liquid to Liquid Heat Exchangers.
The heater shall be designed to allow use with condensing and non-condensing boilers. The heater shall accept boiler water
temperature down to 5°F above desired domestic water temperature, enabling typical condensing boilers to be at condensing inlet
water temperatures, and maximizing system efficiency.
The heat exchanger shall be double wall, and shall be stainless steel construction. It shall be designed to efficiently produce up to
150 gpm of domestic hot water, and DHW temperature set point up to 180°F, depending on system design.
The heater shall be factory assembled, as a skid-mounted package. Each assembled package shall include the heat exchanger,
control valve, interconnecting copper piping, backflush connections, isolation valves, control panel, electrical wiring, temperature
gauge, 150psi T&P relief valve, drain valve, and inlet strainers. Flanged connections shall be used to allow for complete removal of
the heat exchangers without disturbing the water heater piping. The control panel shall be able to be rotated 180° for easy
readability.
The heater assembly shall have a microprocessor-based PID control system with LCD. The control shall use a durable temperature
sensor that transmits a 4-20mA signal through twisted shielded wiring to a 3-way control valve. The system shall manage control
valve to achieve accurate set point, within 4°F of the selected temperature, under varying load patterns, via real-time load tracking.
The control shall be building automation/management system-ready, with RS485 Modbus & BACnet on-board, enable/disable
connection, and the ability to accept a 4-20mA remote temperature set point.
The heater shall have a 120V single phase 60Hz, 15 Amp electrical connection.
The heat exchanger shall carry a five-year non-prorated warranty, and other parts of the assembly shall carry a one-year warranty.
Standard features shall include:
ASME section VIII stamped
Rated in accordance with
ANSI/AHRI Standard 400
PID controller
RS485 Modbus and BACnet
data port
Compatible with BAS/BMS
Audible over-temp alarm
Completely skid-mounted and
wired
Double-wall 316 stainless
steel heat exchanger
3-way control valve
150psi temperature &
pressure relief valve
Backflush connections
Isolation valves
Temperature gauge
Drain valve
Inlet strainers
Compatible with condensing
and non-condensing boilers
5-year heat exchanger
warranty
Brute Plate
COMMERCIAL
INDIRECT WATER
HEATER, MODEL BLP
®