User Manual
Page 4
B
RADFORD
W
HITE
Boiler Type of Valve
Model Size Sufx* Gas Part No. Mfr. No. Manufacturer
BJVS 50-75 D NAT V0077400 VR8304H HONEYWELL
BJVS 100-225 K NAT V0079000 VR8304H HONEYWELL
BJVS 50-75 D LP V0077500 VR8304H HONEYWELL
BJVS 100-225 K LP V0079100 VR8304H HONEYWELL
BJVH 50-160 C NAT V2001800 SV9501H HONEYWELL
BJVH 225 C NAT V2001900 SV9601H HONEYWELL
BJVH 50-225 C LP V2002300 SV9501H HONEYWELL
*Sufx Denitions C = On/Off Firing
D = On/Off Firing
K = Two-Stage Firing
Table 1 - Gas Control Valves
H2360400B
D. Air Shutter Adjustment (when required)
1. STOP! Read the safety information on the last page.
2. Perform a System Start-Up in accordance with
Section A of this manual.
3. Remove the burner cover by loosening the two
thumbscrews.
4. Observe the ame pattern on all burners. If the
ame on any burner is pulsing, unstable or lifting
continue with this procedure. Otherwise skip to
step 10.
5. On all burners exhibiting an abnormal ame, loosen
but do not remove the air shutter locking screw
using a 5/16 inch wrench. (See Fig. 5 below.)
6. On each affected burner, slowly close the air
shutter until a normal ame is observed, then re-
tighten its associated locking screw.
7. Turn the boiler off.
8. Perform a System Start-Up in accordance with
Section A of this manual.
9. Observe the ame pattern on all burners. If
the ame on any burner is pulsing, unstable or
lifting, repeat steps 5 and 6 until all burners are
exhibiting a normal ame.
10. Re-install the burner cover and tighten it in place.
LOCKING SCREW
(5/16" HEAD)
AIR SHUTTER
BURNER
Figure 5 - Removing the Air Shutter Locking Screw
200 Lafayette St.
Middleville, MI 49333
Warranty: (800) 531-2111
www.BradfordWhite.com