MSMD-1119 & MSMD-1119-TS User Guide (451920611082)K5902070/01 05/12/2013
Barco nv President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/esupport Visit us at the web: www.barco.
Table of contents TABLE OF CONTENTS 1. Welcome! .......................................................................................... 3 1.1 1.2 About the product .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 3 What’s in the box. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 3 2. Parts, controls and connectors .....
Table of contents 6. Cleaning instructions ........................................................................... 29 6.1 6.2 Front glass .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 29 Cabinet .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 30 7. Important information ...................
1. Welcome! 1. WELCOME! 1.1 About the product Overview Thank you for choosing this MSMD-1119 or MSMD-1119-TS display! The Barco MSMD-1119 & MSMD-1119-TS is a 19-inch healthcare display specifically designed and certified for use at the point of patient care. Thanks to its excellent image quality, lightweight design and easy-to-wipe protective housing, the MSMD-1119 & MSMD-1119-TS is a perfect fit for hospital computer carts and dental units.
1. Welcome! • • • • • • • • • this MSMD-1119 & MSMD-1119-TS user guide (optional) a VGA video cable (optional) a USB cable (optional) a set of AC power cords (optional) an external +12 VDC power supply (optional) a stand/handle and relevant accessories (optional) a DC extension cable (optional) an IP33 rubber cap (optional) Power supply holder (optional) Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
2. Parts, controls and connectors 2. PARTS, CONTROLS AND CONNECTORS 2.
2. Parts, controls and connectors 2.
3. Installation 3. INSTALLATION About the installation of the display The next section describes how to install your MSMD-1119 or MSMD-1119-TS display. A first subsection shows you how to quickly install your display for use on a desk, without IP protection requirements. The second subsection explains a more detailed installation procedure with IP protection option, VESA arm handle option and detailed cable routing description.
3. Installation 4 3 Image 3-2 3.2 Detailed installation procedure Overview • • • • • • • • 3.2.1 Step Step Step Step Step Step Step Step 1: 2: 3: 4: 5: 6: 7: 8: Stand or handle assembly (optional) Cable routing preparation (optional) Cover removal Cable connection Cable routing Cover reattachment Stand/handle mounting or VESA arm mounting Optional power supply holder Step 1: Stand or handle assembly (optional) To assemble as stand option 1. Fix the 4 rubber pads to the bottom of the stand.
3. Installation 2. Slide the other plastic downwards and press it into the lower plastic so that both are fixed in each other. 2 1 Image 3-4 3.2.2 Step 2: Cable routing preparation (optional) About cable routing preparation In case you will be using the display with the stand/handle option mounted, all cables should be first routed through the stand/handle before connecting or mounting anything else.
3. Installation 1 Table stand option 2 Lower handle option 3 Right handle option 4 Left handle option To prepare the stand/handle and rubber cap for cable routing 1. Route the cables through the appropriate cable gap in the stand/handle. 2. Route the cables through the rubber cap. 1 2 Image 3-6 Warning:The protection against ingress of water IP33 will be void when installing the display without the rubber cap. 3.2.3 Step 3: Cover removal To remove the connector compartment cover 1.
3. Installation 3.2.4 Step 4: Cable connection CAUTION: Make sure that all equipment is switched off before connecting it to the MSMD-1119 or MSMD-1119-TS. Whenever you are mounting the display on the stand/handle or when you are using the rubber cap option, please make sure that all cables are routed through the stand/handle and/or rubber cap before connecting them to the MSMD-1119 or MSMD-1119-TS. To connect the cables 1.
3. Installation 1 3 2 4 5 Image 3-9 3.2.5 1 GND 2 +V 3 4 GND +V 5 Earth Step 5: Cable routing To route the cables 1. Route all connected cables through the cable routing channel. Image 3-10 3.2.6 Step 6: Cover reattachment For displays to be mounted on the stand/handle or on a VESA arm with internal cable routing provisions 1. Slide the connector compartment cover upwards so that it fits onto the display. 2. Reattach the connector compartment cover by tightening the fixation screw.
3. Installation 1 1 2 Image 3-11 For displays to be mounted on a VESA arm without internal cable routing provisions 1. Remove the cable routing expansion clip from the connector compartment cover. 2. Slide the connector compartment cover upwards so that it fits onto the display. 3. Reattach the connector compartment cover by tightening the fixation screw.
3. Installation 1 2 3 4 Image 3-13 1 Table stand option 2 Lower handle option 3 Right handle option 4 Left handle option To mount the display on the stand/handle 1. Mount the display firmly to the stand/handle using 4 M4 screws.
3. Installation Image 3-14 Warning:Please consider the following rule to define an adequate screw length depending on the mounted components: Standard length: 13mm Rubber cap: add 2,5 mm Stand/handle: add 3 mm VESA arm: add VESA plate thickness Tip: The display mounted on the stand can be screwed to the table by using the available holes in the stand. Warning:Pay attention that none of the cables gets pinched between the display and the stand/handle while mounting the display on the stand/handle.
3. Installation 3.2.8 Step 8: Optional power supply holder To mount the power supply holder 1. Partially unscrew the two screws of the foot as shown in the figure below. 2. Put the power supply holder over the two screws. 3. Slide the power supply over the two screws. Image 3-15 4. Fasten the screws of the foot. 5. Slide the power supply in the power supply holder.
4. Daily operation 4. DAILY OPERATION 4.1 Recommendations for daily operation Optimize the lifetime of your display Enabling the Display Power Management System (DPMS) of your display will optimize its diagnostic lifetime by automatically switching off the backlight when the display is not used for a specified period of time. By default, DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to “Power Options Properties” in the “Control Panel”.
4. Daily operation When pressing the Stand-by key ( ) for less than 3 seconds, the shortkey function of this key will be executed instead. Please refer to the dedicated chapter for more information about your display’s shortkey functions. 4.3 OSD menu activation To activate your OSD menu 1. If not already done so, switch on the display by pressing and holding the Stand-by key ( ) for approximately 3 seconds. 2. Press the Menu/Enter key ( ) to activate the OSD menu.
4. Daily operation Overview of shortkeys Keyboard unlocking – Luminance decrease + Luminance increase 4.5.1 Keyboard unlocking To quickly unlock the keyboard 1. While no OSD menu is on the screen, press the Menu/Enter key ( ) shorlty, followed by a press and hold on the Menu/Enter key ( ) until a unlock notification is shown (approximately 5 seconds). 4.5.2 Luminance adjustment To quickly adjust the luminance 1.
4.
5. Advanced operation 5. ADVANCED OPERATION 5.1 Display menu Overview • • • • • • 5.1.1 Source input Luminance OSD menu Advanced menu Power saving Touchscreen (only for MSMD-1119-TS) Source input About source inputs The available source inputs for your display are: • • • DisplayPort HDMI VGA To select the source input 1. Bring up the OSD main menu. 2. Navigate to the Display menu. 3. Enter the Source Input submenu.
5. Advanced operation 5.1.3 OSD menu Overview • • • • • • 5.1.3.1 OSD off timer Languages OSD direction Horizontal OSD position Vertical OSD position Menu blend OSD off timer About OSD off timer The display will automatically exit the OSD menu after the time set in this menu. The available OSD time-out values for your display are: • • • • 5 sec. 10 sec. 20 sec. 4 minutes To select the OSD off timer 1. Bring up the OSD main menu. 2. Navigate to the Display menu, then enter the OSD Menu submenu. 3.
5. Advanced operation • • • • 0° 90° 180° 270° To select the OSD direction 1. Bring up the OSD main menu. 2. Navigate to the Display menu, then enter the OSD Menu submenu. 3. Enter the OSD Direction submenu. 4. Select one of the available OSD menu directions and confirm. 5.1.3.4 Horizontal OSD position To adjust the horizontal OSD position 1. Bring up the OSD main menu. 2. Navigate to the Display menu, then enter the OSD Menu submenu. 3. Enter the H Position submenu.
5. Advanced operation 5.1.4.1 Keyboard lock About the keyboard lock It is possible to lock the keyboard. When locked all keys (except standy key) are locked. To unlock the keyboard see "Keyboard unlocking", page 19. To lock the keyboard 1. Bring up the OSD main menu. 2. Navigate to the Display menu, then enter the Advanced menu submenu. 3. Enter the Keyboard lock submenu. The command bar Keyboard lock is highlighted and a small pointer appears to the left of it. 4.
5. Advanced operation 4. Select the Factory set option and confirm 5.1.5 Power saving About power saving When power saving is enable, the display will go in standby mode (backlight off, low power mode) when no signal is available on the selected input. To enable/disable power saving 1. Bring up the OSD main menu. 2. Navigate to the Display menu. 3. Enter the Power saving submenu. The command bar Power saving is highlighted and a small pointer appears to the left of it. 4.
5. Advanced operation 5.2.2 Phase This menu item is only accessible when VGA input is selected. About phase The Phase can be manually adjusted by following this procedure. To manually adjust the phase 1. Bring up the OSD main menu. 2. Navigate to the VGA menu. 3. Enter the Phase submenu. The command bar Phase is highlighted and a small pointer appears to the left of it. 4. Set the phase as desired and confirm. 5.2.3 Clock This menu item is only accessible when VGA input is selected.
5. Advanced operation 5.2.5 Vertical image position This menu item is only accessible when VGA input is selected. To adjust the vertical image position 1. Bring up the OSD main menu. 2. Navigate to the VGA menu. 3. Enter the V Postion submenu. The command bar V Position is highlighted and a small pointer appears to the left of it. 4. Set the vertical image position as desired and confirm. 5.2.
5.
6. Cleaning instructions 6. CLEANING INSTRUCTIONS 6.1 Front glass WARNING: Before cleaning the front glass, unplug the power cable from the mains. WARNING: Take care not to damage or scratch the front glass. Be careful with rings or other jewelry and do not apply pressure on the front glass. WARNING: Do not apply or spray liquid directly to the front glass as excess liquid may cause damage to internal electronics. Instead, apply the liquid to the cleaning cloth.
6. Cleaning instructions • • • • • • • • • • 6.2 Alcohol/solvents at higher concentration > 5% Strong alkalis lye, strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with steel thread Cabinet WARNING: Before cleaning the cabinet, unplug the power cable from the mains. WARNING: Do not apply or spray liquid directly to the cabinet as excess liquid may cause damage to internal electronics.
7. Important information 7. IMPORTANT INFORMATION 7.1 Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use. Electrical Shock or Fire Hazard To prevent electric shock or fire hazard, do not remove cover. No serviceable parts inside.
7. Important information Power connection • • • • • • • Protective earth: to avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. (Class I Equipment) The equipment must be powered from a center-tapped electrical circuit when used in the USA at voltages above 120 Volts. The medical approved DC power supply must be powered by the AC mains voltage (protective earth terminal). The equipment is intended for continuous operation.
7. Important information Installation precautions • • • • • • • • • • • • • Place the equipment on a flat, solid and stable surface that can support the weight of at least 3 equipments. If you use an unstable cart or stand, the equipment may fall, causing serious injury to a child or adult, and serious damage to the equipment. Do not allow to climb or rest on the equipment. Provide full attention to safety during installation, periodic maintenance and examination of this equipment.
7. Important information EMC notice This device complies with appropriate medical EMC standards on emissions to, and interference from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Interference can be determined by turning the equipment off and on.
7.
7. Important information RoHS Directive 2011/65/EC on the restriction of certain hazardous substances in electrical and electronic equipment (RoHS). Barco manufacturing process does not introduce any non-RoHS material and all the components in this product are RoHS compliant as declared by the respective suppliers. 7.
7. Important information IEC This equipment is intended for use by health care professionals only. This equipment may cause radio interference or may disrupt the operation of nearby equipment. It may be necessary to take mitigation measures, such as reorienting or relocating the or shielding the location.
7. Important information Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the manufacturing date Indicates the temperature limitations1 for the device to safely operate within specs.
7. Important information 7.
7. Important information Screen protection Certifications Non-reflective finished PMMA (non touch version) / Gorilla glass (touch version) The monitor has been certified/registered by the safety agencies as Model No. MED19WDL 93/42/EEC, Amended by 2007/47/EC (Medical device Class I) EN 60601-1: 2006 (3rd Ed) IEC 60601-1 (3rd Ed) ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10) CAN/CSA-C22.2 No.