USER’S GUIDE
Table Of Contents Package Contents Accessories: Sold Separately Product Specifications Intended Use Compatibility ResMed Device Warning Battery Pack Run Times Power Backup Usage Getting Started Turning the Battery Pack On/Off Initial Battery Pack Usage Using the Battery Pack Inside the Carrying Case Control Board Identification The Power Meter Charging the Battery Pack with AC Power Charging the Battery Pack in a Foreign Country Charging the Battery Pack in a Vehicle Powering Your PAP Device Introduction Co
Package Contents The C-100 Battery Pack comes with the items listed below. If you are missing any of these items, please contact the company from whom you purchased the Battery Pack. CARRYING CASE BATTERY PACK(S) CONNECTOR TIPS Battery Pack is sold in a single or dual battery configuration package. AC POWER SUPPLY DC POWER PIGTAIL CORD DC INPUT CORD Accessories: Sold Separately The items listed below are accessories to the C-100 Battery Pack and are not included with the Battery Pack.
Product Specifications DIMENSIONS Size: 7.5” x 4.25” x 0.75” (L x W x H) Weight: 1.6 lbs ELECTRICAL Cell Type: Industrial grade rechargeable lithium-ion Capacity: 100 Wh Output Voltage Range: 9 - 12.6 V Output Current Range: 0 - 4.5 A (8A maximum) Power Gauge: Four stage LED display SAFETY FEATURES Protective Circuit Board (PCB) provides internal protection against thermal runaway (overheating), over charging and discharging, over voltage, over current, and short circuiting.
Intended Use The C-100 Battery Pack is intended to provide external battery power to PAP (positive airway pressure) devices. The Battery Pack may also be used to power other small electronic devices such as smartphones, iPods, laptops, and iPads (use of a sine wave power inverter may be required). See page 19 for more information.
Battery Pack Run Times Multiple factors will affect how long the Battery Pack will power a PAP device, including, but not limited to device type (CPAP, BiLevel, AutoPAP, etc.), pressure setting, altitude, humidifier usage, and if a power inverter or power converter is required in conjunction with the Battery Pack. BiLevel and AutoPAP/APAP devices will generally have lower run times as the pressure setting is not constant and changes throughout the night requiring more power to operate the device.
Power Backup Usage Standard smart chargers keep the Battery Pack topped off and ready to go as an emergency power backup during power outages. If a power outage is immenint or probable, you may connect the PAP device to the Battery Pack and plug the Battery Pack into a wall outlet. In the event power is lost the Battery Pack will automatically begin powering the device.
Getting Started CONTROL BOARD IDENTIFICATION The control board includes the DC in and DC out jacks, charge lights and the power meter, which indicates the remaining power level. E F G A B D A DC In Jack D DC Out Jack G Power Meter C B Power Meter Button E Charging Light C Full Charged Light F On Light On Light (F) will be green when a device is plugged into the DC Out Jack (D) of the Battery Pack. Charging Light (E) will be red when the Battery Pack is being charged.
Charging the Battery Pack with AC Power Connect the AC power cord to the AC power supply. Insert the AC power supply into the DC in jack of the Battery Pack. DUAL BATTERY PACK CHARGING: Insert the AC power supply into the DC power pigtail cord. Insert the DC power pigtail cord into the DC in jacks of both Battery Packs. Plug the AC power supply into a wall outlet. When charging is complete disconnect the AC power supply from the wall outlet and the Battery Pack.
Charging the Battery Pack in a Vehicle When an AC power source is not available the Battery Pack can be safely and efficiently recharged via the cigarette lighter/power socket of a vehicle. To recharge the Battery Pack in this manner you must use either Battery Power Solutions’ Auto Charge DC Cable or 150W Modified Sine Wave Power Inverter (or other comparable sine wave power inverter).
Charging the Battery Pack in a Vehicle CHARGING USING THE AUTO CHARGE DC CABLE Locate the connector tip labeled “N” in the Battery Pack Kit. See page 13 for connector tip identification instructions. Insert the “N” connector tip into the auto charge DC cable. Insert the auto charge DC cable with “N” connector tip attached into the DC in jack of the Battery Pack. DUAL BATTERY PACK CHARGING: Insert the auto charge DC cable with the “N” connector tip attached into the DC power pigtail cord.
Charging the Battery Pack in a Vehicle CHARGING USING THE 150W SINE WAVE POWER INVERTER Insert the AC power supply into the DC in jack of the Battery Pack. DUAL BATTERY PACK CHARGING: Insert the AC power supply into the DC power pigtail cord. Insert the DC power pigtail cord into the DC in jacks of both Battery Packs. Connect the AC power supply to the inverter by sliding open the small spring loaded tab located on the back of the inverter, which will reveal the two-prong plug port.
Powering Your PAP Device: Introduction The C-100 Battery Pack will work with most makes and models of PAP devices; however, the DC capability, voltage requirements and plug polarity of the device will determine how it connects to the Battery Pack. Some PAP devices can be connected directly to the Battery Pack via the DC power pigtail cord; while others will require the additional use of a power converter or power inverter in order to complete the connection between the Battery Pack and the PAP device.
Powering Your PAP Device: Connector Tips Make sure the connector tip sits securely in the DC input port of the PAP device. If the connector tip is loose try another one as you want to avoid using a loose connector tip if there is a better match. Once you have determined the best fitting connector tip, insert it into the DC power pigtail cord and follow the connection instructions for your specific device.
Powering Your PAP Device: Respironics Devices Respironics PAP devices operate from a 12V direct current and may be connected directly to the Battery Pack using the DC power pigtail cord. Insert the DC power pigtail cord into the DC out jack of the Battery. DUAL BATTERY PACK CONFIGURATION: Insert the DC power pigtail cord into the DC out jacks of both Battery Packs. Insert the appropriate connector tip into the DC power pigtail cord. See page 12-13 for connector tip instructions.
Powering Your PAP Device: ResMed S9 Devices ResMed S9 Series devices operate from a 24V direct current so the use of a power converter or sine wave power inverter is required to complete the connection between the device and the Battery Pack. DO NOT connect the Battery Pack directly to any ResMed model device. Battery Power Solutions’ 24V Power Converter was specifically designed for use with ResMed S9 Series PAP devices. Insert the 24V power converter into the DC out jack of the Battery Pack.
Powering Your PAP Device: ResMed S8 Devices ResMed S8 Series PAP device input ports run opposite polarity from other manufacturers so the use of ResMed’s S8 Series DC-12 Converter or a sine wave power inverter is required to complete the connection between the device and the Battery Pack. DO NOT connect the Battery Pack directly to any ResMed model device. Insert the DC input cord into the DC out jack of the Battery Pack.
Powering Your PAP Device: Fisher & Paykel Devices Currently Fisher & Paykel PAP devices do not have a DC capability option and therefore require the use of a sine wave power inverter to complete the connection between the PAP device and the Battery Pack. Battery Power Solutions offers an incredibly small, yet powerful 150 Watt Modified Sine Wave Power Inverter. Insert the DC input cord into the DC out jack of the Battery Pack.
Powering Your PAP Device: DeVilbiss Devices DeVilbiss PAP devices operate from a 12V direct current and may be connected directly to the Battery Pack using the DC power pigtail cord. Insert the DC power pigtail cord into the DC out jack of the Battery. DUAL BATTERY PACK CONFIGURATION: Insert the DC power pigtail cord into the DC out jacks of both Battery Packs. Insert the appropriate connector tip into the DC power pigtail cord. See page 12-13 for connector tip selection instructions.
Powering Other Devices The C-100 Battery Pack can be used to power other small electronic devices such as smartphones, iPads, portable DVD players, and laptops. 12V DEVICES WITH DC CABLE If the electronic device operates from a 12V direct current and has a DC cable with a cigarette lighter plug you can connect the device directly to the Battery Pack using the DC input cord.
Accessories: 150W Sine Wave Power Inverter Sine wave power inverters are used to change direct current (DC) to alternating current (AC). Using a modified or pure sine wave power inverter in conjunction with the Battery Pack allows you to: Power Other Small Electronic Devices To power a small electronic device that does not have a DC cable with a cigarette lighter plug or does not operate from 12V direct current, use a power inverter to complete the connection between the device and the Battery Pack.
Accessories: 150W Sine Wave Power Inverter CONNECTING THE 150 WATT INVERTER TO THE BATTERY PACK Insert the DC input cord into the DC out jack of the Battery Pack. Connect the inverter adaptor cord to the side of the inverter. Insert the cigarette lighter plug end of the inverter adaptor cord into the DC input cord.
Accessories: 24V Power Converter (for ResMed S9 devices) DC to DC power converters convert a source of direct current (DC) from one voltage to another (i.e. 12V to 24V). Power converters are generally proprietary to a specific device. Battery Power Solutions’ 24V Power Converter was specifically designed for use with ResMed S9 Series PAP devices and provides a clean, efficient conversion from 12V to 24V direct current. See page 15 for more information. SPECIFICATIONS Input: 12V / 24V Output: 24V / 3.
Battery Pack Care Instructions Understanding common phenomenon with rechargeable lithium-ion batteries can help you better care for your C-100 Battery Pack and answer many common questions regarding usage. Lithium-ion batteries do not suffer from the memory effects that are associated with other types of battery chemistries. This means that the C-100 Battery Pack does not need to be completely discharged before recharging.
Safety Warnings The following safety warnings must be observed at all times: Do not drop, hit, crush, or otherwise abuse the Battery Pack as this may result in the exposure of the cell contents, which are corrosive. Do not expose the Battery Pack to rain or moisture of any type. Do not expose the Battery Pack to fire, incineration or other extreme heat. Exposure to extreme heat may result in an explosion.
1-877-445-5228 info@batterypowersolutions.net www.batterypowersolutions.
C-100 CPAP BATTERY PACK USER’S GUIDE SEPTEMBER 2014