• Screw down with moment spanner.15kg CAPACITY with 8 NM,
30kg CAPACITY with 10 NM.
• Put the spacer and then screw down 2 screws in it.
• Screw down with moment spanner.15kg CAPACITY with 8 NM,
30kg CAPACITY with 10 NM.
• With X mm ruler to adjust the limit size of back 2 screws. With Y mm ruler to adjust the limit size of front 2
screws inspacer.(capacity:6/15kg X=1.2mmY=0.9mm;capacity:15/30kg X=1.9mmY=1.3mm)
• Insert the loadcell harness to main PCB.
• Install the up cover, print paper cover,up spacer,screws in interface PCB, cover of main PCB at bottom etc.
• Adjust 4 screws in up spacer and let the spacer levelly.
• Put on platter.
• Power on scale.