Data Sheet
Quality and Safety
Listed to UL 1703 Standard for safety by Intertek ETL (Class C fire rating)
Approved by Intertek ETL for use in NEC Class 1, Division 2,
Groups A to D hazardous locations.
Qualification Test Parameters
Temperature cycling range -40°C to +85°C (-40°F to 185°F)
Humidity freeze, damp heat 85% RH
Static load front and back (e.g. wind) 2,400 pa (50psf)
Front loading (e.g. snow) 5,400 pa (113psf)
Hailstone impact 25mm Ø (1 inch) at 23 m/s (52mph)
Module Diagram
Dimensions in brackets are in inches. Un-bracketed dimensions are in millimeters.
Overall tolerances ±3mm (1/8”)
Grounding Detail
50 [2.0]
2.4 [0.09]
27 [1.1]
Section A - A
11.1 [0.44]
TOP VIEW (LID OPEN)
BPJB
(+)
502 [19.8]
FRONT VIEW
Ø9.5
MTG. HOLES
6 PLACES
Ø4(Ø0.2)
GROUND
HOLE
2 PLACES
20
4 PLACES
2.8 MAX
SCREW HEAD
PROJECTION
4 PLACES
595 [23.4]
INCLUDES SCREW HEAD
PROJECTIONS
297 [11.7]
INCLUDING
SCREW HEADS
4 PLACES
BACK VIEW
JUNCTION BOX
467 [18.4]
AA
Included with each module: self-tapping grounding screw, instruction sheet, and warranty document.
Note: This publication summarizes product warranty and specifications, which are subject to change without notice.
Additional information may be found on our web site: www.bpsolar.com
6802.0044 SX330J_D
01
/
10
©BP Solar 2010
SX330 I-V Curves
0.0
0.5
1.0
1.5
2.0
2.5
0 102030
Voltage (V)
Current (A)
t=0C
t=25C
t=50C
t=75C