BPSX310Data Sheet
Quality and Safety
Manufactured in ISO 9001-certified factories; conforms to European Community
Directives 89/33/EEC, 73/23/EEC, 93/68/EEC; certified to IEC 61215
Module power measurements calibrated to World Radiometric Reference through
ESTI (European Solar Test Installation at Ispra, Italy)
Listed by Underwriter’s Laboratories for electrical and fire safety
(Class C fire rating)
Approved by Factory Mutual Research in NEC Class 1, Division 2,
Groups C & D hazardous locations.
Qualification Test Parameters
Temperature cycling range -40°C to +85°C (-40°F to 185°F)
Humidity freeze, damp heat 85% RH
Static load front and back (e.g. wind) 2,400 pa (50psf)
Front loading (e.g. snow) 5,400 pa (113psf)
Hailstone impact 25mm Ø (1 inch) at 23 m/s (52mph)
Module Diagram
Dimensions in brackets are in inches. Un-bracketed dimensions are in millimeters. Overall tolerances ±3mm (1/8”)
2.4 [0.1]
50 [2.0]
Frame Detail
27 [1.1]
11.1 [0.4]
Top View (Lid open)
J-Version
(-)
M-Version
CABLE
421 [16.6]
INCLUDES SCREW HEAD
PROJECTIONS
236 [9.3] DISTANCE BETWEEN
SCREW MOUNTING SLOTS
2.5 MAX
SCREW HEAD
PROJECTION
4 PLACES
269 [10.6]
BACK VIEW
FRONT VIEW
2 CONDUCTOR
4572mm
(-)
(+)
AFFIX GROUND TO
FRAME SCREW AT
ANY OF THE FOUR
CORNERS
M-Version
1.5 [0.1]
23 [0.9]
Frame detail
30 [1.2]
10 [0.4]
Grounding Detail
Grounding Detail
J-Version
Ø9.5
MTG. HOLES
6 PLACES
2.8 MAX
SCREW HEAD
PROJECTION
4 PLACES
GROUND
HOLE
2 PLACES
BACK VIEW
192 [7.6]
4 PLACES
425 [16.7]
INCLUDING SCREW HEAD
PROJECTIONS
238 [9.4]
273 [10.7]
A
FRONT VIEW
A
JUNCTION BOX
GROUND
STAMP
Included with each module: self-tapping grounding screw (J-Version), instruction sheet, and warranty document.
Note: This publication summarizes product warranty and specifications, which are subject to change without notice.
Additional information may be found on our web site: www.bpsolar.com
6802.0042 SX310 M/J_A 06/07
BP Solar 2007
ESTI
SX310 I-V Curves
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0 102030
Voltage (V)
Current (A)
t=0C
t=25C
t=50C
t=75C