Rx Owner’s Handbook
contents pg introduction the gemini range introduction 2 safety notes 3 Thank you for choosing the Bowens Gemini Rx range of monolights. The Gemini monolight is a award-winning, world-class lighting system that has been designed to the highest possible standards.
- do 1.) Switch the power off and disconnect from the power supply before changing the modelling lamps or flash tube. 2.) Disconnect the power supply before changing a fuse. Never replace the fuse with one of a different rating. A spare fuse is located in the fuse holder at the rear of the unit. 3.) Exercise care when handling equipment that has been in use. The reflector and front end of the unit can become very hot. 4.) Avoid placing cables where they can be tripped over.
gemini rx overview G I H F B A C S D J 4 - Gemini Rx | Gemini Rx Overview E A.) Modelling Lamp B.) Flashtube C.) Accessory Release D.) Power Adjust Dial E.) Test Flash & Ready Indicator F.) Carry Handle G.) Trigger Mode Button H.) Photo Slave Cell I.) Pulsar Radio Receiver Antenna K M J.) Lamp Mode K.) Lamp Level L.) Ready Beep M.) 1/4” Sync Socket N.) AC/DC Power Switch L N O Q P R O.) DC Power Input P.) AC Power Input Q.) Fuse Holder R.
using the built-in pulsar changing the pulsar studio/channel setting There are a number of ways to trigger the Gemini Rx monolight. OPEN FLASH (Fig1.)For testing or multiple flash applications the ‘Test Flash’ button can be used. SYNC SOCKET (Fig 2.)- The standard 1⁄4” jack socket on the rear panel of the unit may be used for direct connection to a camera or trigger system. PHOTOCELL (Fig 3.
modelling lamp control unit ready indications flash tube replacement The modelling lamp on the GM200Rx and the GM400Rx uses a phase control system with a soft ‘on’ and ‘off’ to prolong the life of the bulb. A ‘lamp saver’ function has also been incorporated into both units that will automatically turn on if no adjustments are made or flashes fired within 30 minutes. When the ‘lamp saver’ mode turns on the modelling lamp will ‘dim’ to min power.
warning Switch off and disconnect the unit from power supply. If the unit has been in use, allow a sufficient amount of time to cool down before touching. Unscrew modelling lamp from housing and replace with the correct lamp type (see Fig 7.). There are four alarms / warnings on the Gemini Rx to indicate possible function issues. The alarms / warnings are shown via the green ready LED; alarms / warnings may also be accompanied by a beep (if switched on). fuse replacement 1.
auto flash power dump photocell transporting units A resistive dump facility is included on the GM200Rx and GM400Rx, to automatically decrease the power charge should the setting be reduced by the user. This will be indicated by the green ready LED flashing slowly until the power has been ‘dumped’ and the unit is ready at the new desired setting. The unit can also be flashed using the ‘Test Flash’ button to reset the unit to the lower power setting.
All Bowens products are certified by the CE mark. The CE certified mark is a declaration of conformity to the required EEC directives 89/336/EEC ‘Electromagnetic Compatibility’ and 73/23/ EEC ‘Low Voltage Directive’. fcc class b compliance statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: power cables if not installed and used in accordance with the instructions, may cause interference to radio communications.
- Gemini Rx | Trouble Shooting trouble shooting Problem? Check. Problem? Check. Problem? Check. No Power • Check the unit is switched ‘on’. • Check the power cable is inserted correctly. • If using a mains cable, check the fuse on the plug. Unit will not recharge Unit appears ready but won’t fire No Flash • Check flash tube is inserted into the flash head correctly.
Gemini 200Rx (117V) Gemini 400Rx (117V) Gemini 200Rx (230V) Gemini 400Rx (230V) Sync Voltage 5V 5V 5V 5V Colour Temperature 5600K (±300K) 5600K (±300K) 5600K (±300K) 5600K (±300K) Fuse Rating 10A F 10A F 5A F 5A F Supply Voltage AC 95-130VAC 50/60Hz 95-130VAC 50/60Hz 190-250VAC 50/60Hz 190-250VAC 50/60Hz Flash Power Stability ±1% ±1% ±1% ±1% Guide No @ 3m with 50º Keylite 60 80 60 80 Recycle Time (to full) 1.1 seconds 1.65 seconds 0.7 seconds 1.
Rx BWL-0620 | Gemini Rx - 200 and 400 www.bowens.co.