Datasheet
Features
■ Select models are compliant with
AEC-Q200 Rev-C Stress Test Qualifi cation
for Passive Components in Automotive
Applications (see chart below)
■ RoHS compliant*
■ ESD protection >25 kV
■ Low capacitance <0.5 pF
■ Low leakage current <50 nA
Applications
■ HDMI 1.4
■ Digital Visual Interface (DVI)
■ USB 3.0 / USB OTG
■ Memory protection
■ SIM card ports
■ Automotive
ChipGuard
®
MLC Series - ESD Protectors
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
General Information
Electrical Characteristics @ 25 °C (unless otherwise noted)
Parameter Symbol
CG0402MLC-
Unit
3.3LG 05LG 12LG 24LG 3.3LGA 05LGA 12LGA 24LGA
Typical Continuous Operating Voltage V
DC
3.3 5 12 24 3.3 5 12 24 V
Typical Clamping Voltage (Note 1) V
C
25 V
Maximum Capacitance @ 1 VRMS 1 MHz C
O
0.5 pF
Maximum Leakage Current @ Max. VDC I
L
5nA
Typical Trigger Voltage (Note 2) V
T
250 V
Maximum Response Time R
T
1ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
Min. Air Discharge
±8
±15 (Note 3)
±25
kV
kV
kV
Operating Temperature T
OPR
-40 to +85 -40 to +125 ˚C
Storage Temperature T
STG
-55 to +150 ˚C
The ChipGuard
®
MLC Series has been specifi cally designed to protect sensitive
electronic components from electrostatic discharge damage. The MLC family has been
designed to protect equipment to IEC61000-4-2, Level 4 (±8 kV Contact / ±15 kV Air
Discharge) ESD specifi cations targeted for high speed USB 3.0/USB OTG, HDMI 1.4,
DVI or IEEE1394 applications.
The ChipGuard
®
MLC Series has been manufactured to provide low 0.5 pF capacitance
and leakage currents less than 50 nA with excellent clamp qualities, making the family
almost transparent under normal working conditions.
Device Symbol
V
Notes: 1. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement 30 ns after initiation of pulse.
2. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement at maximum pulse voltage.
3. IEC 61000-4-2 ESD Performance for CG0603MLC-05E and CG0603MLC-12E devices will meet minimum 100 reps.
Some shifting in characteristics may occur when tested over several hundred ESD pulses. All other part numbers listed will meet
IEC 61000-4-2 ESD Performance with minimum 1000 reps without degradation in performance.
Parameter Symbol
CG0603MLC-
Unit
3.3LE 05E 05LE 12E 12LE 24LE
3.3LEA
05LEA 12LEA 24LEA
Typical Continuous Operating Voltage V
DC
3.3 5 5 12 12 24 3.3 5 12 24 V
Typical Clamping Voltage (Note 1) V
C
25 20 25 30 25 V
Maximum Capacitance @ 1 VRMS 1 MHz C
O
0.5 pF
Maximum Leakage Current @ Max. VDC I
L
550550 5 nA
Typical Trigger Voltage (Note 2) V
T
250 150 250 150 250 V
Maximum Response Time R
T
1ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
Min. Air Discharge
±8
±15 (Note 3)
±25
kV
kV
kV
Operating Temperature T
OPR
-40 to +85 -40 to +125 ˚C
Storage Temperature T
STG
-55 to +150 ˚C
*RoHS COMPLIANT
AEC APPROVED (Select Models)
AEC Approved Models
Model AEC-Q200
CG0603MLC-05E
✓ Yes
CG0603MLC-12E
✓ Yes