Datasheet

Features
n Low voltage operation
n Low current consumption
n Miniature SMD package size
n I
2
C communication protocol
n Established reliability
n Capacitive technology
Applications
Industrial:
n HVAC systems
n Process monitoring
n Packaging automation
**Medical Devices (low/medium risk):
n Diagnostic equipment
n Analysis equipment
BPS230 Series - 2 mm Humidity Sensor
Absolute Maximum Ratings
Supply Voltage (V
cc
) ............................................................................................................................................................................. -0.3 to 7.0 V
Input Voltage (V
I
)
CE ............................................................................................................................................................................................-0.3 to V
cc
+ 0.3 V
SCL/SDA ........................................................................................................................................................................................... -0.3 to 7.0 V
Output Voltage (VO) ....................................................................................................................................................................-0.3 to V
cc
+ 0.3 V
Hi-level Output Current (IOH)
1 Terminal ................................................................................................................................................................................................... -5 mA
All Terminals Total ..................................................................................................................................................................................... -20 mA
Low-level Output Current (IOL)
1 Terminal .....................................................................................................................................................................................................5 mA
All Terminals Total .......................................................................................................................................................................................20 mA
Operating Temperature (T
a
) ............................................................................................................................. -40°C to +105°C (-40°F to +221°F)
Storage Temperature (T
stg
) .............................................................................................................................. -50°C to +125°C (-58°F to +257°F)
Recommended Operating Conditions
Power Supply Voltage (V
cc
) ........................................................................................................................................................... 1.62 to 5.5 VDC
Capacitance between V
cc
and V
ss
(C
p
) ............................................................................................................................................. 0.1 µF typical
Pull Up Resistor Value on SDA
1
(R1) .................................................................................................................................................... 5 kΩ typical
Pull Up Resistor Value on SCL
1
(R2) .................................................................................................................................................... 5 kΩ typical
1
Select the resistance value to meet AC characteristics.
Electrical Characteristics
Humidity Detection
Measurement Range .................................................................................................................................................................... 0 to 100 % RH
Resolution (10-bit)...................................................................................................................................................................... 0.1 % RH typical
Humidity Accuracy
@ 25 °C (20 to 80 % RH) ............................................................................................................................................................... ±3 % RH
@ 5 °C to 45 °C (0 to 100 % RH) ................................................................................................................................................... ±5 % RH
Hysteresis @ 5 °C to 45 °C (0 to 100 % RH) ............................................................................................................................. ± 1 % RH typical
Response Time
Reach (τ 63 % @ 25 °C, wind velocity @ 1.0 m/s) ...................................................................................................................... 8 seconds
Unless otherwise specied: V
CC
= 1.62 to 5.5 V, V
SS
= 0 V, T
a
= -20 °C to 100 °C
Temperature Detection
Measurement Range ................................................................................................................................ -30 °C to +100 °C (-22 °F to +212 °F)
Resolution (11 bit)
-10 °C to +70 °C .................................................................................................................................................................0.1 °C (32.18 °F)
All other temperatures ........................................................................................................................................................0.4 °C (32.72 °F)
Temperature Accuracy
@ 5 °C to 60 °C .............................................................................................................................................................± 0.4 °C (±32.72 °F)
@ -20 °C to 85 °C ...........................................................................................................................................................± 1.0 °C (±33.8 °F)
Reproducibility @ -30 °C to 100 °C ......................................................................................................................................± 0.1 °C (±32.18 °F)
Response Time
Reach (τ 63 % (dependent on surrounding heat conduction) .................................................................................................... 30 seconds
Unless otherwise specied: V
CC
= 1.62 to 5.5 V, V
SS
= 0 V, T
a
= -30 °C to 100 °C
Current Consumption
Sleep Current (CE=0, Sleep Mode) ........................................................................................................................10 nA typical, 400 nA maximum
Average Operating Current ..................................................................................................................................... 13 µA typical, 35 µA maximum
Unless otherwise specied: V
CC
= 1.62 to 5.5 V, V
SS
= 0 V, T
a
= 0 °C to 60 °C
* RoHS3 Directive 2015/863 Amendments of Annex II on March 31, 2015
** Bourns
®
products have not been designed for and are not intended for use in “lifesaving,” “life-critical” or “life-sustaining” applications nor any other applications
where failure or malfunction of the Bourns
®
product may result in personal injury or death. See Legal Disclaimer Notice on the last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov
*RoHS COMPLIANT
*RoHS & AEC COMPLIANT
*RoHS COMPLIANT
AEC APPROVED (Select Models)
LEAD FREE
*RoHS COMPLIANT
VERSIONS
AVAILABLE
LEAD FREE
VERSIONS ARE
RoHS COMPLIANT*

Summary of content (10 pages)