3382 - 12 mm Rotary Position Sensor
Processing Information
Process Description Materials Temperature Time Interval
1. Apply solder paste to test board Sn/Ag/Cu Alloy water Room temperature
(8 - 10 mil thick) soluble or no clean solder
paste
Single sided epoxy glass
(G10) (UL approved)
PC board approx. 4x4x.06 in.
2. Place test units onto board 6 units/board
3. Ramp up Convection oven 2.5 °C ±0.5 °/second
4. Preheat 150 °C to 190 °C 90 ±30 seconds
5. Time above liquidus 220 °C 60-90 seconds
6. Peak temperature 260 °C +0 °/-5 °
10-20 sec. within 5 °C of peak
7. Ramp down Room temperature 3 °C ±0.5 °C/second
300
255
TEMPERATURE (°C)
220
190
150
0
0 50 100 150
TIME (SECONDS)
200 250
Rotor Dimensions
-1
-2
ORIENTATION FEATURE
4.0 +0.102/-0.051
(.158 +.004/-.002)
DIA.
3.023 ± 0.05
(.119 ± .002)
2.97 ± 0.05
(.117 ± .002)
1.02
(.040)
0.52
(.060)
ORIENTATION FEATURE
3.51 ± 0.05
(.138 ± .002)
DIA.
2.515 ± 0.05
(.099 ± .002)
2.438 ± 0.05
(.096 ± .002)
0.76
(.030))
0.52
(.060)