User`s guide

STEP 5 Communications Setup Selections 19
STEP 5 Communications Setup Selections
To complete this step, you must recall the letters next to the
connections that you made in Step 2.
The procedures below correspond directly to the individual
connections made. Notice that only certain connection
procedures are to be followed, not all of them. For example, if
you have made connections “C” and “F” to a modem and a serial
printer, then follow connection procedures “C” and “F” below.
Only follow those steps that apply to your connections (A-H).
To access the Setup menu, press Ctrl-Scroll Lock on a PC
keyboard or F3 on an ANSI keyboard.
Connection A: Host DCE
1. Enter the Setup menu.
2. In the Setup Quick (F1) menu, set the Host portion of the
“Host/Printer” selection to “EIA” without changing the
current Printer option (“EIA/xxxx”). The Printer will be set in
another connection procedure if needed.
3. In the Ports (F6) menu, set the proper communications
settings for the EIA Baud, EIA Data Format, EIA Parity Check,
EIA Recv, and EIA Xmt selections. See the Setup chapter for
more information on the individual settings.
Connection B: Host DTE
1. Enter the Setup menu.
2. In the Setup Quick (F1) menu, set the Host portion of the
“Host/Printer” selection to “Aux” without changing the
current Printer option (“Aux/xxxx”). The Printer will be set
in another connection procedure if needed.
3. In the Ports (F6) menu, set the proper communications
settings for the Aux Baud, Aux Data Format, Aux Parity