Owner`s manual
29843-5-1012Page 36
OPERATING INSTRUCTIONS
RF VALVE OPERATION
(AF-4044 Electronic Gas Valve system only)
NOTE: THE FIREPLACE WILL ONLY OPERATE WITH THE
HAND HELD REMOTE TRANSMITTER. THE TRANSMITTER
CONTROLS ALL FUNCTIONS OF THE FIREPLACE.
Pleaserefertotheseparateinstructionsfordetailedoperationand
programmingoftheMulti-functionRemoteControl.
The AF-4044 Electronic Gas Control Valve features a Remote
controlled High/Low Variable - 6 Volt DC Motor Drive. This gas
controluses asparktopilotburnerassembly.Foruse withPro-
paneornaturalgas(pre-setatthefactory).
ThisgascontrolsystemincludestheitemsidentiedinFigure 57.
SPECIAL FEATURES ON THE CONTROL MODULE
TheControlModulehastwospecialpilotmodefeaturesbuiltinto
thesystem.
CONTINUOUS PILOT FEATURE: Thisallowstheusertochange
fromasparktopilotsystemtoastandingpilotsystem.
1. There is a switch located on the right side of the Control
Module(#4)thatreadsCONTINUOUSPILOTON/OFF.This
switchwill allow the user to select the pilot mode ofopera-
tion.
2. WhenthecontinuouspilotswitchisintheOFFpositionand
theapplianceturnedON,thepilotwillsparkandlight,thenthe
mainburnerwilllightaswell. When the appliance is turned
OFF,thepilotandmainburnerwillshutOFF.
3. When the continuous pilot switch is in the ON position and
theapplianceisturnedON,thepilotwillsparkandlight.Then
whenthe appliance isturned OFF the pilot will remain ON,
butthemainburnerwillshutOFF.
Note:TheContinuouspilotmodesettingisgenerallyrecom-
mendedon Direct Vent appliances during cold climate sea-
sonstohelpkeepthereboxwarm.
Index No. Description
1 BatteryBack-up
2 AFValve,RF
3 AFControlModule
4 AFExtensionModule
5 ACAdapter
6
PilotAssembly-Nat
PilotAssembly-LP
NotShown RemoteControl
►
◄
▲
▲
▲
▲
1
2
3
4
5
6
Figure 57