Owner`s manual
29843-5-1012 Page 13
Flush Wall Installation
▼
►
▼
▼
HEADER: A DOUBLE HEADER
OR PLACING THE HEADER
VERTICALLY IS RECOMMENDED
STANDOFF 12” (305mm)
HEIGHT ABOVE TOPOF
THE FIREPLACE
FIRST 13-1/2” (343mm)
NON-COMBUSTIBLE
FINISHED WALL
TOP OF THE
FIREPLACE
Figure 14
Combustible Surround Installation
▼
▼
▼
▼
▼
▼
2 X 4
HEADERS
STANDOFFS
COMBUSTIBLE MANTLE
FINISHED WALL
13-1/2” (343mm)
NON-COMBUSTIBLE MATERIAL
SUPPLIED WITH FIREPLACE
NON-COMBUSTIBLE MATERIAL
Figure 15
Framing
Fireplaceframingcanbebuiltbeforeorafterthereplaceisset
inplace.Framingshouldbepositionedtoaccommodatewall
coveringandreplacefacingmaterial.Thereplaceframing
shouldbeconstructedof2x4lumberorheavier.Theframing
headersmayrestonthereplacestandoffs.Refer to Figure 13
for minimum framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
▲
►
▼
◄
◄
►
A
B
C
DVLL/DVTL
A 36-7/8in.(937mm)
B 54-1/2in.(138.4cm)
C 17-1/16in.(433mm)
Figure 13
Framing dimension "A" includes a 12 in. (304 mm)
clearance for standoffs on rebox. After installing rebox
into framing, the nished wall surface must cover the
12 in. (304mm) opening above the rebox. Board provided
with replace.
ATTENTION: Ifabaseormantelisnotusedandtheapplianceis
installeddirectlyoncarpeting,tileorothercombustiblematerialother
thanwoodooring,itshallbeinstalledonametalorwoodpanel
extendingthefullwidthanddepthoftheappliance.Thevertical
dimensioninFigure 13mustbeadjustedwhenametalorwood
panelisplacedbeneaththeappliance.
CAUTION:Ifthejointsbetweenthenishedwallandthereplace
surround (top and sides) are sealed, a 300°F minimum sealant
materialmustbeused.Thesejointsarenotrequiredtobesealed.
Onlynon-combustiblematerial(using300°Fminimumadhesiveif
needed),canbeappliedasfacingtothereplacesurround.
Finishing
Finishthewallswiththematerialofyourchoice.Figure4onpage8
showstheminimumverticalandcorrespondingmaximumhorizontal
dimensionsofmantelsorothercombustibleprojectionsabovethe
topfrontedgeofthereplace.Onlynon-combustiblematerialsmay
beusedtocoverthemetalreplaceface.
INSTALLATION