Owner`s manual

29843-5-1012 Page 13
Flush Wall Installation
HEADER: A DOUBLE HEADER
OR PLACING THE HEADER
VERTICALLY IS RECOMMENDED
STANDOFF 12” (305mm)
HEIGHT ABOVE TOPOF
THE FIREPLACE
FIRST 13-1/2” (343mm)
NON-COMBUSTIBLE
FINISHED WALL
TOP OF THE
FIREPLACE
Figure 14
Combustible Surround Installation
2 X 4
HEADERS
STANDOFFS
COMBUSTIBLE MANTLE
FINISHED WALL
13-1/2” (343mm)
NON-COMBUSTIBLE MATERIAL
SUPPLIED WITH FIREPLACE
NON-COMBUSTIBLE MATERIAL
Figure 15
Framing
Fireplaceframingcanbebuiltbeforeorafterthereplaceisset
inplace.Framingshouldbepositionedtoaccommodatewall
coveringandreplacefacingmaterial.Thereplaceframing
shouldbeconstructedof2x4lumberorheavier.Theframing
headersmayrestonthereplacestandoffs.Refer to Figure 13
for minimum framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
A
B
C
DVLL/DVTL
A 36-7/8in.(937mm)
B 54-1/2in.(138.4cm)
C 17-1/16in.(433mm)
Figure 13
Framing dimension "A" includes a 12 in. (304 mm)
clearance for standoffs on rebox. After installing rebox
into framing, the nished wall surface must cover the
12 in. (304mm) opening above the rebox. Board provided
with replace.
ATTENTION: Ifabaseormantelisnotusedandtheapplianceis
installeddirectlyoncarpeting,tileorothercombustiblematerialother
thanwoodooring,itshallbeinstalledonametalorwoodpanel
extendingthefullwidthanddepthoftheappliance.Thevertical
dimensioninFigure 13mustbeadjustedwhenametalorwood
panelisplacedbeneaththeappliance.
CAUTION:Ifthejointsbetweenthenishedwallandthereplace
surround (top and sides) are sealed, a 300°F minimum sealant
materialmustbeused.Thesejointsarenotrequiredtobesealed.
Onlynon-combustiblematerial(using300°Fminimumadhesiveif
needed),canbeappliedasfacingtothereplacesurround.
Finishing
Finishthewallswiththematerialofyourchoice.Figure4onpage8
showstheminimumverticalandcorrespondingmaximumhorizontal
dimensionsofmantelsorothercombustibleprojectionsabovethe
topfrontedgeofthereplace.Onlynon-combustiblematerialsmay
beusedtocoverthemetalreplaceface.
INSTALLATION