Safety Information
Page 8 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
2.2.2
Voltages under normal conditions (V) .................. :
Within SELV limits
P
2.2.3
Voltages under fault conditions (V) ....................... :
Within SELV limits
P
2.2.4
Connection of SELV circuits to other circuits ....... :
Connect to SELV circuits only
P
2.3
TNV circuits
N/A
2.3.1
Limits
No TNV circuits
N/A
Type of TNV circuits .............................................. :
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed ............................................... :
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed ............................................... :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
P
2.4.1
General requirements
P
2.4.2
Limit values
17.5mA
P
Frequency (Hz) ...................................................... :
25.0K
Measured current (mA) .......................................... :
7.3mA
Measured voltage (V) ............................................ :
14.6V
Measured circuit capacitance (nF or µF) ............... :
CY1=2200pF
2.4.3
Connection of limited current circuits to other
circuits
Connect to SELV circuit only
P
2.5
Limited power sources
N/A
a) Inherently limited output
Not evaluated as limited power
sources, shall be considered
during national approval.
N/A
b) Impedance limited output
N/A
c) Regulating network or IC current limiter, limits
output under normal operating and single fault
condition
N/A