Safety Information

Page 7 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
1.7.8.4
Markings using figures ..........................................:
N/A
1.7.9
Isolation of multiple power sources ........................:
Single power source only
N/A
1.7.10
Thermostats and other regulating devices .............:
No such regulating devices
N/A
1.7.11
Durability
P
1.7.12
Removable parts
No removable parts
N/A
1.7.13
Replaceable batteries .......................................... :
N/A
Language(s) ......................................................... :
1.7.14
Equipment for restricted access locations ............ :
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
P
Test by inspection ................................................. :
Couldn't touch hazardous parts
P
Test with test finger (Figure 2A) ............................ :
Couldn't touch hazardous parts
P
Test with test pin (Figure 2B) ................................ :
Couldn't touch hazardous parts
P
Test with test probe (Figure 2C) ......................... ..:
N/A
2.1.1.2
Battery compartments
No battery compartments
N/A
2.1.1.3
Access to ELV wiring
No ELV circuit
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ..................................................... :
(see appended tables 2.1.1.5)
P
2.1.1.6
Manual controls
No such controls.
N/A
2.1.1.7
Discharge of capacitors in equipment
48V after 1s, limit: 139.12V
P
Measured voltage (V); time-constant (s) ................ :
2.1.1.8
Energy hazards d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the d.c. mains
supply :
N/A
2.1.1.9
Audio amplifiers ..................................................... :
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
P
2.2.1
General requirements
(see appended table 2.2)
P