Safety Information

Page 6 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
Multiple mains supply connections.........................:
Only one mains supply
connection
N/A
Rated voltage(s) or voltage range(s) (V) ...............:
100-240V
P
Symbol for nature of supply, for d.c. only ...............:
N/A
Rated frequency or rated frequency range (Hz) ....:
50/60Hz
P
Rated current (mA or A) ........................................:
1.2A
P
1.7.1.2
Identification markings
P
Manufacturer’s name or trade-mark or identification
mark .......................................................................:
P
Model identification or type reference ...................:
YA40WS-6UT
P
Symbol for Class II equipment only .......................:
used
P
Other markings and symbols .................................:
No give rise to
misunderstanding
P
1.7.1.3
Use of graphical symbols
P
1.7.2
Safety instructions and marking
P
1.7.2.1
General
P
1.7.2.2
Disconnect devices
P
1.7.2.3
Overcurrent protective device
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
N/A
1.7.2.6
Ozone
N/A
1.7.3
Short duty cycles
Continuous operation
N/A
1.7.4
Supply voltage adjustment ...................................:
No supply voltage adjustment
N/A
Methods and means of adjustment; reference to
installation instructions .........................................:
N/A
1.7.5
Power outlets on the equipment ...........................:
No standard power outlets.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .............................:
“F1 T2.5AL 250VAC” marked
on schematic and PCB layout
near fuse
P
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals ..............:
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
N/A
1.7.8.1
Identification, location and marking .........................:
N/A
1.7.8.2
Colours ...................................................................:
N/A
1.7.8.3
Symbols according to IEC 60417.............................:
N/A