Safety Information
Page 11 of 13
Report Ref. No.: 68.210.18.0104.01
Attachment No. 1
IEC60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Test Report National and Group Differences for IEC 60950-1 2
nd
Ed.+A1+A2 Rev. 10
US United States of America
US
3.3.5
First column of Table 3E revised to require
“Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.”
N/A
3.4.2
Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the "on"
position indicated by the handle in the up position.
N/A
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA30.
N/A
4.3.13.5.
1
Equipment with lasers is required to meet the U.S.
Code of Federal Regulations 21 CFR 1040 (and
the Canadian Radiation Emitting Devices Act,
REDR C1370).
N/A
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 0.76 m
3
(27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m
2
(10 sq ft) or a single dimension greater than
1.8 m (6 ft) are required to have a flame spread
rating of 50 or less. For other applications,
enclosures with the same dimensions require a
flame spread rating of 200 or less.
N/A
4.7.3.1
Non-metallic enclosures of equipment for use in
spaces used for environmental air (plenums) are
required to comply with UL 2043.
N/A
Annex H
Equipment that produces ionizing radiation is
required to comply with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
N/A
OTHER NATIONAL DIFFERENCES