Safety Information
Page 9 of 13
Report Ref. No.: 68.210.18.0104.01
Attachment No. 1
IEC60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Test Report National and Group Differences for IEC 60950-1 2
nd
Ed.+A1+A2 Rev. 10
US United States of America
US
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS
1.1.1
All equipment is to be designed to allow
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I, CAN/CSA
C22.1, and when applicable, the National
Electrical Safety Code, IEEE C2. Also, unless
marked or otherwise identified, installation is
allowed per the Standard for the Protection of
Electronic Computer/Data-Processing Equipment,
ANSI/NFPA 75.
P
1.1.2
Baby monitors are required to additionally comply
with ASTM F2951, Consumer Safety Specification
for Baby Monitors.
N/A
1.4.14
For Pluggable Equipment Type A, the protection in
the installation is assumed to be 20A.
P
1.5.5
For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable assemblies
are required to be a suitable cable type (e.g., DP,
CL2) specified in the NEC.
For lengths 3.05 m or less, external
interconnecting flexible cord and cable assemblies
that are not types specified in the NEC are
required to have special construction features and
identification markings.
N/A
1.7.1
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase conductor
(e.g. 120/240 V, 3-wire) require a special marking
format for electrical ratings.
A voltage rating that exceeds an attachment plug
cap rating is only permitted if it does not exceed
the extreme operating conditions in Table 2 of
CAN/CSA C22.2 No. 235, and if it is part of a
range that extends into the Table 2 "Normal
Operating Conditions." Likewise, a voltage rating
shall not be lower than the specified "Normal
Operating Conditions," unless it is part of a range
that extends into the "Normal Operating
Conditions."
N/A
1.7.7
Wiring terminals intended to supply Class 2
outputs in accordance with the NEC or CEC Part
1 shall be marked with the voltage rating and
“Class 2” or equivalent. The marking shall be
located adjacent to the terminals and shall be
visible during wiring.
N/A
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
N/A