Safety Information
Page 4 of 13
Report Ref. No.: 68.210.18.0104.01
Attachment No. 1
IEC60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Test Report National and Group Differences for IEC 60950-1 2
nd
Ed.+A1+A2 Rev. 10
CA Canada
CA
1.7.7
Wiring terminals intended to supply Class 2
outputs in accordance with CEC Part 1 or NEC
shall be marked with the voltage rating and
“Class 2” or equivalent. Marking shall be located
adjacent to the terminals and shall be visible
during wiring.
N/A
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
N/A
2.6
Equipment with isolated ground (earthing)
receptacles is required to comply with NEC
250.146(D) and CEC 10-112 and 10-906(8).
N/A
2.7.1
Suitable NEC/CEC branch circuit protection rated
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent
protection.
N/A
3.2
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
N/A