Safety Information

Page 42 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
C.2
TABLE: transformers (T1)
P
Loc.
Tested insulation
Working
voltage
peak / V
(2.10.2)
Working
voltage
rms / V
(2.10.2)
Required
electric
strength
(5.2)
Required
clearanc
e / mm
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
Required
distance thr.
insul.
(2.10.5)
T1
primary/core
to secondary
Reinforced
648
285
3000VA
C
4.7
5.8
*
Loc.
Tested insulation
Test
voltage/V
AC
Measure
d
clearanc
e / mm
Measure
d
creepage
dist./ mm
Measured
distance thr.
insul. / mm;
number of
layers
T1
primary/core
to secondary
Reinforced
3000VA
C
6.5
6.5
Triple
insulation
wire used
as
secondary
winding
Supplementary information:
- Core of transformer T1 was considered as primary parts.
- *: 1 layers of insulation tape/0.4mm thickness/triple insulation wire complied with Annex U.