Safety Information
Page 41 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
C6
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
Q3 pin D-S
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
# R22
S-C
240VAC
10mins
F1
>5.25→
0
F1 opened immediately after
short circuit, No hazard.
R62
S-C
240VAC
10mins
F1
0.449
Unit normal work after short
circuit. No damage, no hazard.
R9
S-C
240VAC
10mins
F1
0.449
Unit normal work after short
circuit. No damage, no hazard.
U4 pin 1-5
S-C
240VAC
10mins
F1
0.337
TYPE C output shut down
immediately after short circuit.
USB output normal work, No
damage, no hazard.
U7 pin 1-5
S-C
240VAC
10mins
F1
0.337
USB output shut down
immediately after short circuit.
TYPE C output normal work, No
damage, no hazard.
Supplementary information:
1) S-C: short-circuited; O-C: open-circuited O-L: overloaded;
2) SELV outputs did not exceed 42.4Vpeak or 60Vd.c. for longer than 0.2 secs and did not exceed the limit
of 71Vpeak or 120Vpeak after abnormal tests were applied.
3) The electric strength tests were successfully conducted after the completion of fault tests.
4) # Denoted that the tests were performed on all alternate fuses, all results were same.
5) Unless otherwise specified, all above tests were conducted at loading: TYPE-C output: 5VDC/0A,
USB1/USB2/USB3: 5VDC/2.4A, USB4: 5VDC/0.8A.
6) T1 limit: 165°C.