Safety Information

Page 40 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
# C1
S-C
240VAC
10mins
F1
>5.25→
0
F1 opened immediately after
short circuit, No hazard.
Q1 pin G-S
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
# Q1 pin G-D
S-C
240VAC
10mins
F1
>5.25→
0
F1 opened immediately after
short circuit, No hazard.
# Q1 pin D-S
S-C
240VAC
10mins
F1
>5.25→
0
F1 opened immediately after
short circuit, No hazard.
U1 pin 2-5
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U1 pin 1-5
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U1 pin 1-6
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U1 pin 2-6
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
T1 pin 1-2
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
T1 pin 4-6
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
T1 pin A-B
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U2 pin 1-2
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U2 pin 3-4
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.
U2 pin 2
O-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
open circuit. No damage, no
hazard.
U2 pin 4
O-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
open circuit. No damage, no
hazard.
Q2 pin D-S
S-C
240VAC
10mins
F1
0.015
Unit shut down immediately after
short circuit. No damage, no
hazard.