Safety Information

Page 39 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
Component
No.
Fault
Supply
voltage
(V)
Test
time
Fuse #
Fuse
current
(A)
Observation
TYPE-C output
O-L
240VAC
6hrs
40mins
F1
Max.
0.466
The maximum TYPE-C output
loaded current was 3.60A
(USB1/USB2: 2.4A, USB3: 0.2A,
TYPE-C: 3.60A) and ran for
thermal equilibrium under it.
TYPE-C output over 3.60A unit
shut down immediately. Other
USB output normal work, No
damage, no hazard.
T1 winding: 92.5°C,
T1 core: 81.0°C,
Ambient: 27.3°C
USB terminal
O-L
240VAC
7hrs
43mins
F1
Max.
0.459
The maximum USB output loaded
current was 8.70A
(USB1/USB2/USB3: 2.4A, USB4:
1.50A) and ran for thermal
equilibrium under it. USB output
total over 8.70A unit shut down
immediately. TYPE C output
normal work, No damage, no
hazard.
T1 winding: 92.1°C,
T1 core: 80.6°C,
Ambient: 26.9°C
T1 pin A to pin
B after Q2
O-L
240VAC
7hrs
43mins
F1
Max.
0.511
T1 output Max. extra load current
was 0.70A and ran for thermal
equilibrium under it. Over it unit
shutdown immediately, no
damaged, no hazard.
T1 winding: 98.4°C,
T1 core: 87.9°C,
Ambient: 26.3°C
USB1 output
S-C
240VAC
10mins
F1
0.337
USB output shut down
immediately after short circuit.
TYPE C output normal work, No
damage, no hazard.
TYPE C output
S-C
240VAC
10mins
F1
0.337
TYPE C output shut down
immediately after short circuit.
USB output normal work, No
damage, no hazard.
# BD1
S-C
240VAC
10mins
F1
>5.25
0
F1 opened immediately after
short circuit, No hazard.