Safety Information

Page 38 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
5.1
TABLE: touch current measurement
P
Measured between:
Measured
(mA)
Limit
(mA)
Comments/conditions
L/N and plastic enclosure with
metal foil
0.01
0.25
Normal operation.
L/N and output terminals
0.154
0.25
Normal operation.
supplementary information:
- Input voltage: 264V, 60Hz
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
P
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
Test voltage
(V)
Breakdo
wn
Yes / No
Functional:
--
--
--
--
Basic/supplementary:
L to N (fuse F1 disconnected)
AC
1500
No
Reinforced:
L/N and output terminals
AC
3000
No
L/N to plastic enclosure with metal foil
AC
3000
No
Transformer T1: primary and secondary
AC
3000
No
Transformer T1: core and secondary
AC
3000
No
Insulation sheet above of power supply board
AC
3000
No
Heating shrinkable tube (used on F1 )
AC
1500
No
Supplementary information:
Core of transformer T1 was considered as primary parts.
5.3
TABLE: Fault condition tests
P
Ambient temperature (C) ................................... :
See below
Power source for EUT: Manufacturer, model/type,
output rating ......................................................... :
--