Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
4.3.8
TABLE: Batteries
N/A
Battery category .......................................... :
(Lithium, NiMh, NiCad, Lithium Ion …)
Manufacturer ............................................... :
Type / model ................................................ :
Voltage ........................................................ :
Capacity....................................................... :
mAh
Tested and Certified by (incl. Ref. No.) ....... :
Circuit protection diagram:
MARKINGS AND INSTRUCTIONS (1.7.13 )
Location of replaceable battery
Language(s) …………………………………….:
--
Close to the battery …………………………….:
--
In the servicing instructions ……………………:
--
In the operating instructions …………………..:
--
4.5
TABLE: Thermal requirements
P
Supply voltage (V) ................. :
90V,
60Hz
--
264V,
50Hz
--
Ambient T
min
(C) ................... :
40.0
--
40.0
--
Ambient T
max
(C) .................. :
40.0
--
40.0
--
Maximum measured temperature T of
part/at:
T (C)
Allowed
T
max
(C)
AC inlet
57.6
--
52.7
--
70
PCB near BD1
83.4
--
68.3
--
130
CX1 body
85.3
--
72.6
--
100
LF1 winding
114.0
--
84.7
--
130
C1 body
103.6
--
88.6
--
105
PCB near Q1
107.3
--
95.2
--
130
T1 winding
108.6
--
102.5
--
110
T1 core
96.6
--
91.5
--
110
PCB under T1
99.6
--
93.9
--
130
U2 body
94.2
--
92.1
--
100
CY1 body
102.6
--
100.0
--
125