Safety Information

Page 33 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
2.10.2
Table: working voltage measurement
P
Location
RMS voltage (V)
Peak voltage (V)
Comments
T1 pin 1 and pin A
182
354
--
T1 pin 2 and pin A
184
434
T1 pin 4 and pin A
278
634
--
T1 pin 6 and pin A
240
344
--
T1 pin 1 and pin B
180
382
--
T1 pin 2 and pin B
186
480
--
T1 pin 4 and pin B
278
648
Max. Vpeak
T1 pin 6 and pin B
285
352
Max. Vrms
CY1 primary to secondary
176
352
--
U2 pin 1 and pin 3
177
352
--
U2 pin 1 and pin 4
178
352
--
U2 pin 2 and pin 3
179
358
--
U2 pin 2 and pin 4
179
358
--
supplementary information:
Input voltage: 240VAC, 60Hz, output loading: TYPE-C output: 5VDC/0A, USB1/USB2/USB3: 5VDC/2.4A,
USB4: 5VDC/0.8A.
2.10.3 and
2.10.4
TABLE: Clearance and creepage distance measurements
P
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
Functional insulation:
L to N before fuse F1
340
240
1.5
3.3
2.4
3.3