Safety Information
Page 14 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
3.1.9
Termination of conductors
P
10 N pull test
P
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
P
3.2.1
Means of connection
Appliance inlet used
P
3.2.1.1
Connection to an a.c. mains supply
P
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
P
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
AC power supply cords not
provided for evaluation, shall
be considered during national
approval
N/A
Type ...................................................................... :
Rated current (A), cross-sectional area (mm
2
),
AWG ..................................................................... :
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :
Longitudinal displacement (mm) .......................... :
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
Detachable power supply cord
used
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
Radius of curvature of cord (mm) .......................... :
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
No such wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A