Safety Information

Page 12 of 43
Report Ref. No.: 68.210.18.0104.01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
TRF No. IEC60950_1F
For a d.c. mains supply ......................................... :
N/A
b) Transients from a telecommunication network :
N/A
2.10.4
Creepage distances
P
2.10.4.1
General
P
2.10.4.2
Material group and comparative tracking index
P
CTI tests................................................................. :
Material group IIIb was
assumed for others.
2.10.4.3
Minimum creepage distances
(see appended table 2.10.3
and 2.10.4)
P
2.10.5
Solid insulation
P
2.10.5.1
General
P
2.10.5.2
Distances through insulation
(see appended table 2.10.5)
P
2.10.5.3
Insulating compound as solid insulation
P
2.10.5.4
Semiconductor devices
Approved optocoupler (U2)
used
P
2.10.5.5.
Cemented joints
N/A
2.10.5.6
Thin sheet material General
N/A
2.10.5.7
Separable thin sheet material
N/A
Number of layers (pcs) .......................................... :
2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material standard test procedure
N/A
Electric strength test
2.10.5.10
Thin sheet material alternative test procedure
N/A
Electric strength test
2.10.5.11
Insulation in wound components
P
2.10.5.12
Wire in wound components
P
Working voltage .................................................... :
(see appended table 2.10.2)
P
a) Basic insulation not under stress ...................... :
N/A
b) Basic, supplementary, reinforced insulation ..... :
N/A
c) Compliance with Annex U ................................ :
Approved triple insulated wire
TIW used, comply with Annex
U
P
Two wires in contact inside wound component;
angle between 45 and 90 .................................. :
Separated by insulation tube
P
2.10.5.13
Wire with solvent-based enamel in wound
components
N/A
Electric strength test
Routine test
N/A