Manual Firmware V1.3.7

6. In ‘Input-Switch’ , you can select the protocol with which you want to receive the data at
the serial interface ( ‘ArtNet’ or ‘sACN’ ).
7. To set the backlight in ‘Backlight’ , select the value ‘Disable’ (no backlight) or a value of
‘1 Min’ ‘60 Min’ (duration of illumination). If no action is taken on the device within
the set time, the backlight turns o.
8. Turn keylock on and o in ‘KeyLock’ .
Press for 3 seconds if you want to activate the display while the keylock is activated.
9. For the DMX intervals in output mode, select a value of ‘25’ ‘100’ (unit ms) in ‘DMX-
Interval’ .
10. In ‘Factory’ , you can reset the device to factory default settings.
1. ‘Version’ displays the current software version.
2. ‘Devices’ shows how many RDM devices are connected to the respective interface (dis‐
play shows ‘Port1:0’ ‘Port8:0’ ).
The lock screen displays:
Display of the settings
Lock screen
Operating
24
NETcon 8-3 / 8-5
ArtNet DMX converter