Manual Firmware V1.3.7
Table Of Contents
6. In ‘SwIn’ , enter a value between ‘0’ and ‘15’ for the lower 4 bits of the 15-bit address of
the input in the ArtDMX.
1. Select ‘sACN-Cong’ to enable sACN and set the domain area for the sACN protocol.
2. Select ‘Enable’ and then the option ‘On’ or ‘O’ to enable or disable sACN.
3. In ‘Universe’ , choose a value between ‘00001’ … ‘63999’ .
1. Select ‘Settings’ to make general settings.
2. In ‘Sub-Mask ’ , select one of the three address ranges.
3. In ‘Local IP’ , enter the desired local IP address of the device.
4. In ‘Broadcast’ , in Input mode, select the option ‘Broadcast’ or ‘Unicast’ .
5. In ‘Target IP’ under ‘All’ , enter an IP destination address uniformly for all 8 interfaces, or
under ‘IP1’ … ‘IP8’ , enter a separate IP destination address for each interface. The rst
byte of the IP address is not displayed. The ‘Target IP’ is relevant when the device should
receive DMX signals and transform them into ArtNet or sACN signals and output them.
Conguring sACN
Settings
Operating
NETcon 8-3 / 8-5
23
ArtNet DMX converter