Manual Firmware V1.3.7
Table Of Contents
Display Name Function
‘I’ DMX input When an interface is set to input mode and DMX data is
received at the interface, the data is sent immediately to the
congured IP address or via the broadcast device via
ArtDMX. If the 15-bit interface address matches, the other
device will accept the DMX data.
‘R’ RDM In RDM mode, the interface initiates a test of the device after
power up or after changing the interface mode, and incre‐
mentally checks the device every 3 seconds. When the ArtNet
controller issues an ArtTodRequest instruction, the converter
immediately creates a list of the UIDs of the connected
devices. It supports ArtRdm when sending other RDM
instructions.
‘U’ Online
upgrade
This is the support function of the device. Here you can
update the converter yourself or the device that is in connec‐
tion mode through the interface through an encrypted
upgrade le provided by the ArtFirmwareMaster instruction.
Operating
20
NETcon 8-3 / 8-5
ArtNet DMX converter