Manual Firmware V1.3.6

8. Turn keylock on and o in ‘KeyLock’ .
Press for 3 seconds if you want to activate the display while the keylock is activated.
9. For the DMX intervals in output mode, select a value of ‘25’ ‘100’ (unit ms) in ‘DMX-
Interval’ .
10. In ‘Factory’ , you can reset the device to factory default settings.
1. ‘Version’ displays the current software version.
2. ‘Devices’ shows how many RDM devices are connected to the respective interface (dis‐
play shows ‘Port1:0’ ‘Port8:0’ ).
The lock screen displays:
1. In the rst line: the local IP address of the device
2. In the second line: Value of the ArtNet universe (calculated from Net Switch, Sub Switch,
and Interface 1 value)
3. In the third line: Value of the sACN universe
Display of the settings
Lock screen
Operating
26
NETcon 8-3 / 8-5
ArtNet DMX converter