Manual Firmware V1.3.6

If eight interface addresses of the device match, they are treated as one interface. For example,
if Interface 1 and Interface 2 are set to 0x0000, the DMX data sent by the ArtNet controller to
the 0x0000 interface will be simultaneously transmitted to both interfaces.
For the sACN protocol, the interface address corresponds to the universe and the value for the
universe is the address of interface 1 and is then incremented with the interfaces (the universe
at interface 1 is 1, the universe at interface 2 is 2, etc.). The converter sends DMX data to the
appropriate interface associated with the universe in the sACN packets sent by the converter.
1. Select ‘ArtNet-Cong’ to set up the network connections.
2. In ‘Net Switch’ , enter a value between ‘0’ and ‘127’ for the upper 7 bits of the 15-bit
address in the ArtDMX.
3. In ‘Sub Switch’ , enter a value between ‘0’ and ‘15’ for the middle 4 bits of the 15-bit
address in the ArtDMX.
4. In ‘SwOut’ , enter a value between ‘0’ and ‘15’ for the lower 4 bits of the 15-bit address
of the output in the ArtDMX.
5. In ‘SwIn’ , enter a value between ‘0’ and ‘15’ for the lower 4 bits of the 15-bit address of
the input in the ArtDMX.
Conguring ArtNet
Operating
24
NETcon 8-3 / 8-5
ArtNet DMX converter