3. Use the jog wheel to select the setting to be changed and press the jog wheel. Turn the
jog wheel to select or adjust a value. The following table shows the menu items and
choices.
Menu item Choices Meaning
‘TX Start Code’ ‘0’ … ‘255’ Start value for the DMX data transmission.
‘RX Start Code’ ‘0’ … ‘255’ , ‘All’ This code is required if several test devices should work as trans‐
mitters. In this case, all test devices must be set to the same
code. If you select ‘All’ , the device accepts all start codes.
‘Auto Identify’ ‘Auto’ Automatically sending a request for identication to all con‐
nected devices when selecting the menu item ‘Get&Set RDM
Parameter’ .
‘OFF’ No automatic request for identication.
‘16bit Format’ ‘MSB rst’ In 16-bit mode: higher-value byte rst
‘LSB rst’ In 16-bit mode: higher-value byte last
‘Format’ ‘Decimal’ , ‘Percents’ , ‘BAR
(square)’ , ‘Hexadezimal’
Selection of the display format for numerical values: decimal,
percentage, as a bar or hexadecimal
‘Contrast Level’ ‘10’ … ‘100’ Display contrast setting