HIF-2121/R5 CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 965-1176-601 REV: D SHEET 35
FLUID SUSCEPTIBILITY X No test required
SAND AND DUST X No test required
FUNGUS RESISTANCE F No test (non-nutrient material certification) required
SALT SPRAY X No test required
MAGNETIC EFFECT Z Less than 0.3m
POWER INPUT A Normal:22.0-30.3VDC
Abnormal: (5 minutes) 20.5-32.3VDC
Emergency: 18VDC
interrupt for 200msec
Normal Surge (30msec): 15-40VDC
Abnormal Surge: 100msec @ 46.3VDC,
1 sec @ 37.8VDC
VOLTAGE SPIKES A 600VDC, 10µs, 50source impedance
AUDIO FREQ. CONDUCTED SUSCEPTIBILITY Z 0.20Vrms 10-200Hz
0.56 Vrms 200-1,000Hz
1.40Vrms 1,000-15,000Hz
0.20 down to 0.001Vrms, 15kHz – 150KHz
INDUCED SIGNAL SUSCEPTIBILITY C Magnetic, unit: 20Arms @ 400Hz
Magnetic, cables: 60A-m @ 400Hz down to 1.6A-m
@ 15kHz
Electric, cables: 5400V-m, 380-420 Hz
Induced Spikes: 600V p-p, 2-10µs rate, 3 meters.
RF CONDUCTED SUSCEPTIBILITY R 10kHz – 500MHz: 0.6mA – 30.0 mA
500kHz – 400 MHz: 30.0 mA
RF RADIATED SUSCEPTIBILITY R 20 V/m, 0.1 – 0.4 GHz, SW & CW
150 V/m, 0.4 – 8 GHz, Pulse.
RF CONDUCTED EMISSIONS M Power: 53 – 20 dBµA @ 0.15 – 2MHz,
20 dBµA@>2MHz
Cables: 73–40dBµA @ 0.15 – 2MHz,
40 dBµA@>2MHz
RF RADIATED EMISSIONS M Complex curves with notches (see DO160D)
LIGHTNING INDUCED TRANSIENT A3E3 Pin: 600V/24A, 300V/60A
SUSCEPTIBILITY Cable: 300V/600A, 600V/120A
LIGHTNING DIRECT EFFECTS X No test required
ICING X No test required
ELECTROSTATIC DISCHARGE TEST A 15,000 Volts