Technical data

Product Specification
HIF-2121/R5 CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 965-1176-601 REV: D SHEET 129
The RS-232 port will default to the following characteristics: 19,200 baud, 8 bits, no parity, and 1 stop bit. The other
potential baud rate settings is 38400. The baud rate 38400 will be used for file/database loading only.
See section 6.10.4 for a description of the EGPWC front panel test plug connections required to support RS-232
communications.
6.10.10 Data Loading Interface
The EGPWC has the capability of having software, or databases, updated by using a PCMCIA card. (See Figures 6.10.10-1
MKVI/MKVIII EGPWS Serial I/O).
When Data Loading is allowed, all internal databases will be able to be loaded into the EGPWC via the data-loading
interface. These databases include, but are not limited to, the following:
1) Terrain Database,
2) Runway Database,
3) Obstacle Database,
4) Configuration Database.
5) Envelope Modulation Database.