6.10.6.3 Level 3 Self-Test - System Configuration
Level 3 self-test provides enunciation of the system configuration present at the time of the request. Level 3 self-test is
initiated by pressing the cockpit self-test button within 3 seconds of the end of level 2 self-test. The process is described in
Figure 6.10.6-5 and includes the information as described in table 6.10.6-1.
During level 3 self-test, a Short Cancel bumps the enunciation to the next level 3 item (e.g. from terrain database information
to Envelope Modulation database information).
During level 3 self-test, a Long Cancel terminates the self-test level and “PRESS TO CONTINUE” is annunciated for
proceeding to level 4 self-test.
START
LEVEL 4
START
LEVEL 3
SHORT
CANCEL
LEVEL 3
COMPLETE
No
ANNUNCIATE
"PRESS TO
CONT"
Yes
No
SWITCH
PRESSED
WITHIN
3 SEC
No
Yes
LONG
CANCEL
No
SKIP TO NEXT
LEVEL 3 ITEM
Yes
ANNUNCIATE
"FAULT
HISTORY"
Yes
STOP SELF TEST
FIGURE 6.10.6-5: LEVEL 3 SELF-TEST
1. Part Number
2. Mod Status
3. Serial Number
4. Application Software Version
5. Terrain Database Version
6. Envelope Modulation Database Version
7. Boot Code Version
8. Aircraft Type
9. Air Data Type
10. Radio Altitude Type
11. Navigation Input Type
12. Attitude Input Type
13. Magnetic Heading Type
14. Position Input Type
15. Callouts Option
16. Audio Menu
17. Volume Select
18. Terrain Display Type
19. IO Discrete Type
20. Windshear Type
21. All other selected options from the configuration module. Refer to MKVI/MKVIII EGPWS Installation
Design Guide. Note that only those features that are enabled or disabled from the basic configuration
are annunciated.