Technical data

Product Specification
HIF-2121/R5 CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 965-1176-601 REV: D SHEET 120
6.10.6.1.3 Long Level 1 Self-Test
The long level 1 self-test is initiated by pressing and holding the cockpit self-test button until self-test voices start. The long
level 1 self-test annunciates all configured and activated alert voices, including warning voices, caution voices and altitude
callout voices. If activated, the long level 1 self-test is initiated immediately following the short level 1 self-test. The results
are described in Figure 6.10.6-3.
"Minimums-
Minimums"
voice*
Callouts
enabled?
Bank Angle
enabled?
"Bank Angle"
voice
Yes
No
Approaching
Minimums
enabled?
Approaching
Minimums
Type Callout
Yes
No
Minimums
enabled?
Configured
Minimums-
Type Callout
Yes
No
Altitude
Callouts for the
selected menu
Smart
Callout
Selected?
"500" foot
Smart Callout
Yes
No
WS
enabled?
Yes
WS
Caution
enabled?
Configured Caution
Windshear
voice
Yes
No
Configured
Windshear
voice
No
Terrain
Clearance
Floor
enabled?
Configured
TCF voice
Yes
No
TA&D
enabled?
Configured
Terrain
Warning voice
Yes
No
Configured
Terrain
Caution voice
"Sinkrate" voice
Mode 1
Pull-UP voice
"Terrain" voice
"Don't Sink"
voice
"Too Low
Terrain",
"Too Low Gear",
"Too Low Flap",
"Too Low Terrain"
voices
"Glideslope"
voice
Mode 2
Pull-UP voice
Yes
Continue
to Level Two
Self Test ?
No
Self Test
Complete
START
LEVEL 2
Start Long Portion of
Level One Self Test
ANNUNCIATE
"CURRENT
FAULTS"
Signal TA&D
to return display to
original state
No
If off, Turn on:
GPWS INOP
Windshear INOP
Terrain INOP
Terrain NA
Configured
Obstacle
Warning voice
Configured
Obstacle
Caution voice
Speed
Brake
Enabled
?
"Speed Brake"
voice
Yes
N
o
Obstacle
Enabled ?
Yes
Yes
No
Note1,3
Note1,3
Note 4
Note: Windshear will be included as a future MKVIII EGPWS application.
FIGURE 6.10.6-3: LONG LEVEL 1 SELF-TEST