Service manual

24
MZ-NE410
Laser Power Check and Adjustment
Connection
Checking and adjusting method
1. Select the manual mode of test mode (see page 14), and set the
laser power adjusting mode (item number 010).
2. Press the . key continuously until the optical pick-up moves
to the most inward track.
3. Open the cover and set the laser power meter on the objective
lens of the optical pick-up.
4. Press the > key, and set the laser MO read adjustment mode
(item number 011).
5. Check that the laser power meter reading is 0.754 ± 0.13
mW.
6. If the reading value is not satisfied, adjust with the
[VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the ENT/u key to write the ad-
justed value.
7. Press the > key, and set the laser CD read adjustment mode
(item number 012).
8. Check that the laser power meter reading is 0.896 ± 0.16 mW.
9. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the ENT/u key to write the ad-
justed value.
10. Press the > key, and set the laser MO (X2 speed) write
adjustment mode (item number 013).
11. Check that the laser power meter reading is 4.93 ± 0.59 mW.
12. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the ENT/u key to write the ad-
justed value.
13. Press the > key, and set the laser MO (X4 speed) write ad-
justment mode (item number 014).
14. Check that the laser power meter reading is 5.98 ± 0.71mW.
15. If the reading value is not satisfied, adjust with the [VOL +]
or [VOL --] key so that the power meter reading becomes the
specification value. Press the ENT/u key to write the ad-
justed value.
16. Press the x/CANCEL key to quit the manual mode, and ac-
tivate the test mode (display check mode).
laser
power mete
r
optical pick-up
objective lens
Set LCD display
Laser
010
Set LCD display
###S**
011
address adjusted value
Set LCD display
###S**
012
address adjusted value
Set LCD display
###S**
013
address adjusted value
Set LCD display
###S**
014
address adjusted value
Overall Adjustment Mode
Configuration of Overall Adjustment Mode
Overall Adjustment Mode (Title Display)
Note: Adjust the CD first, when performing adjustment.
: (Disc mark) At end of power supply adjustment: Outside lit
**: Left side = MO overall adjustment information
F*: MO overall adjustment completed
1*: Manual adjustment exists (overall adj. not completed)
0*: Not adjusted
Right side = CD overall adjustment information
*F: CD overall adjustment completed
*1: Manual adjustment exists (overall adj. not completed)
*0: Not adjusted
Set LCD display
Assy**
000
Overall adjustment mode
(Title display)
"Assy**"
Continuing overall adjustment
. key
> key
CD overall
adjusting
MO overall
adjusting
Electrical
offset
adjustment
Temperature
correction
and
Power supply
adjustment
auto item feed
[VOL +] key
[VOL -] key
x/CANCEL key